6
there are emergencies.
J6 Drop Arm:
Short circuit DOW and GND, the arm is dropped down by force in case there are fires or other emergencies.
J8 Proximity Switch Signal Input:
Input position signal of the arm.
J9 12V Power Supply for Access control:
control board directly provide Access Control with 12V power. (Maximum
support 3A)
V1L Left Solenoid, V2R Right Solenoid & UP D50 Solenoid:
Control the passage and arm dropping.
4.2 Connection diagram of the access controller device
Figure 4-2
Warning: Forbidden using an electrically charged objects to connect to any one port of Opening Signal Input,
otherwise will damage the control board.
4.3 DIP K1 switch configuration
Figure 4-3
Pin
1
2
3
4
5
6
7
8
Function Setting
Opening Duration Direction Indicator Continue Passing Function Alarm
Default
1
1
1
0
1
0
0
0
4.3.1 Setting the turnstile opening duration
Opening duration refers to the period of time from opening to closing once the turnstile receives an open signal. In the DIP
switch, number 1, 2, and 3 are used for duration setting. It can be set to different values from 5s to 60s according to the
following chart.
Bit Setting Duration Bit Setting Duration
111
5s
011
30s
110
10s
010
40s
101
15s
001
50s
100
20s
000
60s
Note:
The turnstile opening duration is set to 5s by default.
Note:
The lock relay duration of access
controller device needs to be set to 1s.