4.3.2 Direction indicator
It is to indicate whether the passage allows people to pass. The green arrow means passing is allowed while the red "
X
"
means passing is prohibited. The indicator status can be set through number 4 and 5 in the DIP switch. The description of
the bit settings are as follows:
11
= One-way traffic, left passing is allowed.
10
= One-way traffic, right passing is allowed.
01
= Passing is allowed in both directions.
4.3.3 Continue passing function
With the Continue Passing function, the turnstile could remember at most 20 swipes of one card at one time and allows up
to 20 people to pass so they don’t have to swipe card each time, this function can be enabled or disabled through number
6 in the DIP switch. The description of the bit settings are as follows:
In the DIP switch, number 6 is used to enabled or disabled the
Continue Passing Function
, number 7 is used to set the
initial value of
Continue Passing Function
.
number 6
number
7
Function
Opening Duration
0
disabled
Disabled
Continue Passing
Function
Please consult
4.3.1 Setting the Turnstile Opening Duration
1
1
Enabled
Continue Passing
Function
The initial value is 16s, and the
Opening Duration
= 16 +
(N -1) * 6
0
The initial value is 8s, and the
Opening Duration
= 8+ (N
-1) * 6
4.3.4 Alarm function (optional)
In the DIP K1 switch, number 8 is used to enabled or disabled the
Alarm Function
.
1 = enabled
0 = disabled
Note
: Please set to 0 when working normally, that is to say that
Alarm Function
is disabled.