background image

 

4.3 Parameter Configuration 

Function description of the DIP switch 

Down position 

indicates value 1.

Up position 

indicates value 0.

 

            Figure 4-3 

Pin 

Function Setting 

Opening Duration  Direction Indicator  Memory Function 

 

4.3.1 Setting the Turnstile Opening Duration 

Opening duration refers to the period of time from opening to closing once the turnstile receives an open signal.   
In the DIP switch, number 1, 2, and 3 are used for duration setting. It can be set to different values from 5s to 60s according to the 
following chart. 

Duration 

Bit Setting 

Duration 

Bit Setting 

5s 

000 

30s 

001 

10s 

100 

40s 

101 

15s 

010 

50s 

011 

20s 

110 

60s 

111 

Note: 

The turnstile opening duration is set to 5s by default. 

4.3.2 Direction Indicator 

It is to indicate whether the passage allows people to pass. The green arrow means passing is allowed while the red "X" means passing is 
prohibited. The indicator status can be set through number 4 and 5 in the DIP switch. The description of the bit settings are as follows: 

00

 = One-way traffic. Green indicator indicates that passing is allowed while red indicator indicates that passing is prohibited. 

10

 = One-way traffic. Green indicator indicates that passing is allowed while red indicator indicates that passing is prohibited. 

01

 = Passing is allowed in both directions. 

4.3.3 Memory Function 

With the memory function, the turnstile could remember at most 20 swipes of one card at one time and allows up to 20 visitors to pass 
so they don’t have to swipe card each time, this function can be enabled or disabled through number 6 in the DIP switch. The description 
of the bit settings are as follows: 

ON 

(up): indicates that the memory function is enabled. 

OFF 

(down): indicates that the memory function is disabled. 

5. Equipment Precautions and Maintenance 

5.1 Precaution 

1.

 

It is recommended to purchase optional accessories to use in outdoor environment. 
(1)

 

It shall install optional cooling fans for the equipment if the working temperature is often above 50 ºC. 

(2)

 

It is equivalent to IP54 waterproof under proper installation. However, it cannot work in the region that may suffer typhoon. 

(3)

 

If the temperature is -30ºC, a heating plate is suggested to install. It might need multiple times to power on while getting hot 
automatically through the self-check program. 

(4)

 

The service life of this equipment may be shortened if it works outdoors in coastal areas or a region prone to acid rain. 

2.

 

If the power and signal cables are connected properly, this equipment can be immersed in water of 250 mm deep, but it must not be 
powered on for operating when it is immersed in water. 

3.

 

It is highly recommended that a card swiping warning line to set for prompting passers-by to swipe cards properly and a reasonable 
passage width shall be set to prevent passers-by from squeezing in illegally. 

Summary of Contents for TS2200 Series

Page 1: ...ght 65kg Operating Humidity 5 85 Gross Weight 75kg Flow Rate 25 48 passages minute Dimension mm Figure 1 L 1110 W 320 H 980 Input Control Signal Dry contact Package Size mm L 1200 W 440 H 1080 1110 98...

Page 2: ...turnstile to finish the self check program 3 Lift the arms manually as shown in figure 2 4 4 Check whether the tripod turnstile and the LED indicators work properly If there is any problem please ref...

Page 3: ...to Ground earth there is wiring interface in the power switch Figure 3 3 3 3 Installation 1 Drilling holes Drill holes based on the locations of the holes shown in figure 3 3 2 Fix the mounting plate...

Page 4: ...ive relay signal and open the turnstile Emergency Switch to keep the turnstile open in case there are fire or other emergencies Direction Indicator Output to connect a LED screen and indicate whether...

Page 5: ...3 Memory Function With the memory function the turnstile could remember at most 20 swipes of one card at one time and allows up to 20 visitors to pass so they don t have to swipe card each time this...

Page 6: ...for more than 6s and then lift the arms manually 5 2 Maintenance Forming maintenance consciousness The tripod turnstile needs to be maintained regularly and repaired once it is damaged It is recommend...

Page 7: ...s not open after authentication It may be caused by lack of permission or a circuit problem 1 Check whether the user has the permission to open the turnstile 2 Use a multimeter to check whether the NO...

Page 8: ...cation TCP IP 192 168 1 201 5 Turnstile Opening Duration 5s 6 Passing Direction Indicator Passing is allowed Green Arrow 7 Memory Function Disabled Note The Lock Driving Duration is default 5 seconds...

Page 9: ...9 Attachment 2 Connection Diagram Overview...

Page 10: ...10...

Reviews: