5
4.3 Parameter Configuration
Function description of the DIP switch
Down position
indicates value 1.
Up position
indicates value 0.
Figure 4-3
Pin
1
2
3
4
5
6
Function Setting
Opening Duration Direction Indicator Memory Function
4.3.1 Setting the Turnstile Opening Duration
Opening duration refers to the period of time from opening to closing once the turnstile receives an open signal.
In the DIP switch, number 1, 2, and 3 are used for duration setting. It can be set to different values from 5s to 60s according to the
following chart.
Duration
Bit Setting
Duration
Bit Setting
5s
000
30s
001
10s
100
40s
101
15s
010
50s
011
20s
110
60s
111
Note:
The turnstile opening duration is set to 5s by default.
4.3.2 Direction Indicator
It is to indicate whether the passage allows people to pass. The green arrow means passing is allowed while the red "X" means passing is
prohibited. The indicator status can be set through number 4 and 5 in the DIP switch. The description of the bit settings are as follows:
00
= One-way traffic. Green indicator indicates that passing is allowed while red indicator indicates that passing is prohibited.
10
= One-way traffic. Green indicator indicates that passing is allowed while red indicator indicates that passing is prohibited.
01
= Passing is allowed in both directions.
4.3.3 Memory Function
With the memory function, the turnstile could remember at most 20 swipes of one card at one time and allows up to 20 visitors to pass
so they don’t have to swipe card each time, this function can be enabled or disabled through number 6 in the DIP switch. The description
of the bit settings are as follows:
ON
(up): indicates that the memory function is enabled.
OFF
(down): indicates that the memory function is disabled.
5. Equipment Precautions and Maintenance
5.1 Precaution
1.
It is recommended to purchase optional accessories to use in outdoor environment.
(1)
It shall install optional cooling fans for the equipment if the working temperature is often above 50 ºC.
(2)
It is equivalent to IP54 waterproof under proper installation. However, it cannot work in the region that may suffer typhoon.
(3)
If the temperature is -30ºC, a heating plate is suggested to install. It might need multiple times to power on while getting hot
automatically through the self-check program.
(4)
The service life of this equipment may be shortened if it works outdoors in coastal areas or a region prone to acid rain.
2.
If the power and signal cables are connected properly, this equipment can be immersed in water of 250 mm deep, but it must not be
powered on for operating when it is immersed in water.
3.
It is highly recommended that a card swiping warning line to set for prompting passers-by to swipe cards properly and a reasonable
passage width shall be set to prevent passers-by from squeezing in illegally.