background image

 

 

Add Device 

After searching, select the 

Standalone Terminal

 

and click [Add Device], and a dialog box will open. 

Enter self-defined device name, device type set to Standalone Device and click [OK] to complete 
device adding.

 

 

Note: 

The default IP address of the Standalone Terminal may conflict with the IP of a device on the 

Internet. You can modify its IP address: Click [Modify IP Address] behind the device and a dialog box 
will open. Enter the new IP address and other parameters (Note: Must configure the gateway and IP 
address in the same network segment). 

2)

 

Register the UHF tag 

Connect the UHF Card Issuer to a computer; click the 

Personnel Profile 

tab to register the UHF 

tag, as shown in the figure below: 

 

Summary of Contents for U1000E

Page 1: ...1 User Manual UHF RFID Standalone Terminal Version 1 0 Date December 2017...

Page 2: ...rize 1 2 UHF RFID Standalone Terminal 1 3 Parameters Specifications 2 4 Safety Precautions 3 5 Modifying Setting via Demo 3 6 Access to Software 5 6 1 Access to ZKAccess 5 6 2 Access to ZKBioSecurity...

Page 3: ...e parking lot and access control system Meanwhile the utility model has the advantages of stable reading performance good consistency low working current and temperature long service life and small ex...

Page 4: ...Wiegand Signal Wiegand input output Working Frequency F 902Mhz 928MHz E 865MHz 868MHz Support Card Tag1 Tag2 Tag3 Tag4 DF01Card DF02 Card UHF Interface Protocol EPC global UHFClass1Gen2 ISO18000 6c A...

Page 5: ...recommended to use DC12V 3A power supply 2 Please wire according to the cable definition 5 Modifying Setting via Demo 1 USB Connection 2 Software Introduction Our company provides Demo used to set the...

Page 6: ...ets the time interval between adjacent wiegand data Reader Indicate Set whether the buzzer rings when the machine is on the electricity and brush the card Work Mode Set the working mode of the machine...

Page 7: ...ard is read within the scope of the card to the card is left out of the scope of the card to read the second time card 6 Access to Software RJ45 Connection Connect the RJ45 port of the Standalone Term...

Page 8: ...the Standalone Terminal may conflict with the IP of a device on the Internet You can modify its IP address Click Modify IP Address behind the device and a dialog box will open Enter the new IP address...

Page 9: ...All Data and click OK to complete synchronization The system will synchronize the data to the device including door information access control levels personnel information access control time zones a...

Page 10: ...y recognition mode long distance access control gets rid of the passive recognition of the shackles really realize the Hand Free model Remote sensing automatic reading card automatic identification wi...

Page 11: ...r tag4 pasted on the interior windshield of car and parking barrier When the car pulls up the range of the U2000 Standalone Terminal the authorized tag mounted on car will be identified then reading i...

Page 12: ...le environment the Standalone Terminal may fail to read the card due to the overlarge reading angle You can install an additional Standalone Terminal at the corner to solve the problem For such terrai...

Page 13: ...KTeco Logo is a registered trademark of ZKTeco or a related company All other product and company names mentioned are used for ZK Building Wuhe Road Gangtou Bantian Buji Town Longgang District Shenzhe...

Reviews: