background image

UHF10 Pro Reader

User Manual

P a g e

| 19

Copyright©2021 ZKTECO CO., LTD. All rights reserved.

7

Installation Procedure

1.

Please install the directional antenna with a lower elevation angle of
60° to 75° to suit the correct line ofsight.

Note:

Please install the reader as shown in the above picture. The facing direction of
the reader and the travel direction of the vehicle must be in a straight line. The
distance between the reading head and the parking barrier must be
maintained at 50cm or more.

2.

Avoid installing the reader opposite to each other.

Summary of Contents for UHF10F Pro Reader

Page 1: ...March2021 Doc Version 1 0 English Thank you for choosing our product Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please visit our Company s website www zkteco com ...

Page 2: ...ts hereof should not be used or shared by the receiver with any third partywithout expresswritten permission ofZKTeco The contents of this manual must be read as a whole before starting the operation and maintenanceofthesupplied equipment Ifanyofthe content s of the manual seems unclear or incomplete please contact ZKTeco before starting the operation and maintenance ofthe said equipment It is an ...

Page 3: ...event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages including without limitation loss of business loss of profits business interruption loss of business information or any pecuniary loss arising out of in connection with or relating to the use of the information contained in or referenced by this manual even if ZKTeco has been...

Page 4: ...the machine and equipment in conditions differentfrom theprescribed conditionsofthemanual The product will be updated from time to time without prior notice The latest operation procedures and relevant documents are available on http www zkteco com If there is any issue related to the product please contact us ZKTecoHeadquarters Address ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Don...

Page 5: ...ependent research and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With the continuous enhancement of the development and plenty of market applications the team has gradually constructed an identity authentication ecosystem and smart security ecosystem which...

Page 6: ...of Contents 1 OVERVIEW 6 2 SIDE VIEW WIRING 7 3 SPECIFICATIONS 8 4 DIMENSIONS 9 5 SOFTWARE CONFIGURATION 9 INTRODUCTION 10 5 1 1 MAIN INTERFACE 10 5 1 2 RS485 SETTING INTERFACE 14 5 1 3 SYSTEM SETTINGS 16 6 ACCESS CONTROLLER CONNECTION 18 7 INSTALLATION PROCEDURE 19 8 WIRING DIAGRAM 21 9 FAQ 21 ...

Page 7: ...ter recognition speed It is equipped with a passive UHF card which could be widely used in Vehicle management and Personnel management applications The product also meets the CE FCC technology requirements and yet to obtain the CE FCC and other security certifications UHF10F Pro Antennaoperatingfrequency Malaysian Frequency 919 5 923 0MHz Card reading range UHF10F Pro hand held test up to 20m driv...

Page 8: ...2021 ZKTECO CO LTD All rights reserved 2 Side View Wiring Mounting Bracket Cables USB No Colour Connection 1 Red DC 12V 2 Black GND 3 Green Wiegand D0 4 White Wiegand D1 5 Purple TriggerPoint 6 Gray GND 7 USB Connect to PC 8 Brown RS485 9 Orange RS485 ...

Page 9: ...Hz supports adjustment Communication interface Wiegand RS485 USB Configuration parameters Wiegand RS485 requires one of the two options Interface Protocol EPC global UHF Class 1 Gen 2 ISO 18000 6C Working Mode Read Always Default Read by Trigger Output Power 19dBm to 30dBm Protection Class IP66 WorkingVoltage DC 9to15V Working Temperature andHumidity 20 to 65 85 Storage Temperature andHumidity 20 ...

Page 10: ...UHF10 Pro Reader User Manual P a g e 9 Copyright 2021 ZKTECO CO LTD All rights reserved 4 Dimensions UHF10F Pro 5 Software Configuration ...

Page 11: ...yright 2021 ZKTECO CO LTD All rights reserved Introduction 5 1 1 Main Interface Take the operation of the American standard reader as an example Reader Connection Click Connect to connect the Reader and click Disconnect to disconnect the Reader ...

Page 12: ... Work Mode Configuration Click ReadAlwaysto make the Reader always in the read status Click Readby Triggerto enable the reader to read only after it is triggered RF Settings The RF Settings helps to set the Power and Frequency values Buzzer Select the Buzzer check box to enable the Buzzer ...

Page 13: ... Forward Output and Inverted Output Click Forward Output to read the card number in the partition in the progressive order and click Inverted Output to read out the card number in thepartitioninthereverseorder customersneednotset OutputDuration Setting The time of continuous output signal of the reader can be set and the maximum setting time is 1s ...

Page 14: ...KTECO CO LTD All rights reserved Wiegand FormatSetting The default Wiegand format is WG26 and it can be set as WG34 WG42 WG50 WG58 WG66 WG74 WG82 WG90 WG98 Card Reading IntervalSetting Youcan set the card reading interval to prevent the repeated card reading ...

Page 15: ...5 Setting Interface Thecontrollers supported bydefaultareinbio260 and inbio460 Baud RateSetting The default Baud rate is 96000 and it can be adjusted as per the requirements Device Address Setting The Device Address Setting is used to distinguish the readers which are installed in different locations ...

Page 16: ...esponding data after receiving the card search command Select Auto Work to read the card and automatically upload the data tothe Controller RS485OutputMode The RS485 Output Settings consist of Forward Output and Inverted Output Click Forward Output to read the card number in the partition in the progressive order and click Inverted Output to read out the card number in thepartitioninthereverseorde...

Page 17: ...021 ZKTECO CO LTD All rights reserved 5 1 3 System Settings LEDLightSetting The LED indicator color can be set in the Standby Status and the Read Card Status There are seven colors to choose System Settings Set the location of the data import and export ...

Page 18: ...TD All rights reserved CardReaderOutput There are 3 Card Reader output modes namely Wiegand Mode RS485 mode andTCP IPmode Language Settings Right clickin the blank area ofthe Demo interface apop up appears as shown below click Language Settings to select the language ...

Page 19: ...UHF10 Pro Reader User Manual P a g e 18 Copyright 2021 ZKTECO CO LTD All rights reserved 6 Access Controller Connection ...

Page 20: ...levation angle of 60 to 75 to suit the correct line ofsight Note Please install the reader as shown in the above picture The facing direction of the reader and the travel direction of the vehicle must be in a straight line The distance between the reading head and the parking barrier must be maintained at50cm ormore 2 Avoid installing the reader opposite to each other ...

Page 21: ...rong magnetic field while working Recommended tags Type Picture Explanation UHF1 Tag1 card Operating frequency 840 to 960MHz Data Storage 32 bit TID 64 bit Unique TID 96 bit EPC 512 bit User Supported Protocol EPC global class 1 Gen2 ISO18000 6C Product size 85 6x54 0x0 8mm UHF Parking Tag Parking lotlabel Operating frequency 840 to 960MHz Data Storage 32 bit TID 64 bit Unique TID 96 bit EPC 512 b...

Page 22: ...g e 21 Copyright 2021 ZKTECO CO LTD All rights reserved 8 Wiring Diagram 9 FAQ What to do if the recognition distance of the reader is too close Try the following possibilities Connect the demo and then adjust the power to the maximum ...

Page 23: ...lace the tag or reader What can be done if the reader doesn t read the card Try the following possibilities When the reader is connected to DEMO you need to click Disconnect so that it could read the card again Connect the Demo to check whether the manual card reading is normal If the manual card reading does not respond there is a problem with the reader If the manual card reading fails after the...

Page 24: ...he barrier port iscorrect Check whether the barrier is open when the UP and GND terminals are short circuited If not the barrier isfaulty Check whether the tag has registered the information on the software and the data is synchronized to the reader When swiping the card pay attention to whether the controller has the sound of relay jumping and whether the software has the normal door opening reco...

Page 25: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2021 ZKTECO CO LTD All Rights Reserved ...

Reviews: