background image

 

11 

2. The indicator turns red and makes a long beep in fourth step indicates system 
exits when setting successfully.   

2.3 Configure Authentication Mode 

1. The administrator 
password is authenticated. 

2. Press5. 
(The indicator turns green 
and makes a long beep.)

3. Enter the authentication 
mode.

5.Exit. 
(The device automatically 
exits the process when the 
operation is completed.)

4.The configuration is 
successful.
(The indicator turns green 
and makes a long beep, 
then turns red and makes a 

long beep again.)

 

Note: 1.The indicator turns red and makes a long beep in fourth step indicates 

system exits when setting successfully. 

2. Details about the authentication mode are as follows: 

Authentication Mode 

type

 

Description

 

Mode 1 (number1) 

PW 

Only password verification   

Mode 2 (number2) 

RF 

Only RF Card verification 

Mode 3 (number3) 

FP 

Only fingerprint verification 

Mode 4 (number4) 

FP/PW/RF 

fingerprint or password or RF verification 

Mode 5 (number5) 

RF&PW 

RF and password verification 

Mode 6 (number6) 

FP&PW 

fingerprint and password verification   

 

2.4 Configure Concealed Mode 

If the Concealed mode is enabled, the indicator is off when the Concealed mode 
is in the sleep mode. 

Поставщик систем безопасности: TELECAMERA.RU

Summary of Contents for X7

Page 1: ...Produced by ZKTeco Inc System User Manual X7 Access Control Поставщик систем безопасности TELECAMERA RU ...

Page 2: ... be triggered 3 If the device being illegally removed the device will export alarm signal 4 External exit button is supported it is convenient to open the door inside 5 External bell is supported 1 Equipment Installation 4 Fix the device to the back cover 5 Fix the screw 1 Remove the screw on the bottom of device 2 Take away the back cover 3 Fix the back cover on the wall according to the mounting...

Page 3: ...ode equipped in the package to prevent the self inductance EMF affect the system do not reverse the polarities I Share power with the lock II Does not share power with the lock I I device output current ULOCK lock voltage ILOCK lock current Device share power with the lock ULOCK 12V I ILOCK 1A And the lock is near to the device Device does not share power with the lock A ULOCK 12V I ILOCK 1A B ULO...

Page 4: ...or Alarm Input DC 12V 500mA 50mA standby Positive is connected with 12V negative is connected with GND do not reverse the polarities 4 Connected with Other Parts 5 Connect with Power Поставщик систем безопасности TELECAMERA RU ...

Page 5: ... Administrator Authentication Change Administrator Password Open the Door by the Administrator Password Administrator Password Be Forgotten 1 2 Add Users Add Users Register Cards in Batches 1 3 User Authentication 1 4 Delete Users Delete a User Delete All Users 2 Access Control Management 2 1 Set Change Eight Passwords for Opening the Door 2 2 Configure Unlocking Duration 2 3 Configure Authenticat...

Page 6: ...or password is 1234 You are advised to change the initial password at the beginning Change Administrator Password 1 The administrator password is authenticated 2 Press 8 You can change the password 3 Enter a new administrator password YES 5 Succeeded The indicator turns green and makes a long beep 4 Enter the new administrator password again for authentication 6 Exit The device automatically exits...

Page 7: ...isassembled from the wall or door 1 2 Add Users Register the fingerprint or card of a user or register cards in batches Add Users 1 The administrator password is authenticated 2 Press 1 The indicator turns green and makes a long beep 3 Register fingerprints or cards Press fingers three times to get a fingerprint or swipe the card once Yes 5 Exit Press to exit 4 Adding Users is successful The indic...

Page 8: ...turns red and makes three beeps YES Yes Note 1 In the process of entering the total number of cards three digit numbers are automatically verified For numbers with less than three digits press to enter the verification process Press to reenter the total number of cards 2 You must clear all the registered users before registering cards in batches IDs of to be registered cards must be consecutive nu...

Page 9: ...se fingerprint or card is registered or delete all users Delete a User 1 The administrator password is authenticated 2 Press2 The indicator turns green and makes a long beep 3 Enter a user ID press the fingerprint or swipe the card YES 5 The user is deleted The indicator turns green and makes a long beep then turns red and makes a long beep again 4 Determine whether the user is authentic 6 Exit Pr...

Page 10: ...tically exits the process when the operation is completed 4 Deleting All Users is successful The indicator turns green and makes a long beep then turns red and makes a long beep again Note 1 Press 9 for automatic confirmation Other values are considered invalid If an invalid value is entered the device indicator turns red and the device makes a long beep and exits the process 2 The indicator turns...

Page 11: ...ight passwords for opening the door is empty 2 If a password is successfully changed enter the password ID of the to be changed password to change the next password 2 2 Configure Unlocking Duration 1 The administrator password is authenticated 2 Press 4 The indicator turns green and makes a long beep 3 Enter the unlocking duration range 0 to 255 5 Exit The device automatically exits the process wh...

Page 12: ...Note 1 The indicator turns red and makes a long beep in fourth step indicates system exits when setting successfully 2 Details about the authentication mode are as follows Authentication Mode type Description Mode 1 number1 PW Only password verification Mode 2 number2 RF Only RF Card verification Mode 3 number3 FP Only fingerprint verification Mode 4 number4 FP PW RF fingerprint or password or RF ...

Page 13: ...or Mode The door sensor switch includes three modes NONE The door sensor switch is not used NO The lock is open as long as the door is open NC The lock is closed after the door is closed 1 The administrator password is authenticated 2 Press0 The indicator turns green and makes a long beep 3 Press 5 The indicator turns green and makes a long beep 5 The configuration is successful The indicator turn...

Page 14: ... process when the operation is completed Note The indicator turns red and makes a long beep in fifth step indicates system exits when setting successfully Configure Error Operation Triggered Alarm If this function is enabled alarms are generated if an administrator fails the authentication upon three attempts The administrator authentication is not allowed within 20 seconds after an alarm is gener...

Page 15: ...g successfully Configure Alarm Delay for the Door Status Sensor DSen Delay Door Sensor Delay indicates the delay in checking the door sensor after the door is open If door sensor state is inconsistent with the normal state set by the door sensor switch an alarm will be generated and this period of time is regarded as the door sensor delay 1 The administrator password is authenticated 2 Press0 The ...

Page 16: ...er the verification process Values greater than 254 are considered invalid 2 The indicator turns red and makes a long beep in fifth step indicates system exits when setting successfully Поставщик систем безопасности TELECAMERA RU ...

Reviews: