Walk through Metal Detector with Turnstile 

ZK-MD6000 Series 

Date: October 2022   

Doc Version: 1.2 

English 

Summary of Contents for ZK-MD6000 Series

Page 1: ...arefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please vis...

Page 2: ...s in and is the property of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of this manual must b...

Page 3: ...information is assumed by the user ZKTeco in no event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages including without limitatio...

Page 4: ...ration of the machine and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The latest operation procedu...

Page 5: ...arch and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With...

Page 6: ...onvention Description Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi le...

Page 7: ...reserved Table of Contents 1 NOTE 7 2 PRODUCT SPECIFICATION 8 3 INSTALLATION ENVIRONMENT 10 4 PERFORMANCE AND FEATURES 11 5 PARTS 12 6 INSTALLATION 13 7 DETECTION ZONES 17 8 OPERATION 18 SYSTEM MENU B...

Page 8: ...where the reflection or light is not strong enough to affect face recognition 4 Choose a stable installation location to avoid false alarms caused by excessive shaking of the product 5 Make sure that...

Page 9: ...as it may cause false alarms 12 This is not a medical device and the data cannot be used for medical purposes It is just used to check your body temperature 2 Product Specification ZK MD6000 series W...

Page 10: ...crowd rush walk slowly or crush the door panel 4 Before passing through the metal detector the pedestrians must remove all the carried metal objects such as keys mobile phone watch coins etc and plac...

Page 11: ...and fixed to avoid false alarm after installation by the movement of people walking or moving and shaking of metal objects 4 Electromagnetic Radiation and Electromagnetic Interference As the device us...

Page 12: ...rding to the actual environment and the operating frequency selected by the walk through metal detector 4 Performance and Features Enhanced Detection 33 detection zones and 500 sensitivity levels Ther...

Page 13: ...nual and Installation Guide P a g e 12 Copyright 2022 ZKTECO CO LTD All rights reserved 5 Parts 1 Door Panel 2 Main Box 3 Access Control Device 4 Entrance Control Device 5 Cameras and Thermal Imaging...

Page 14: ...ter reading the installation precautions and checking the packing list Step 1 Unpack the package and place the left and right door panels on the ground with the power boards of the two door panels fac...

Page 15: ...ctor on the rear of the turnstile and insert the wires protruding from the lower part of the walk through metal detector into the left and right chassis from the back of the turnstile Step 5 Connect t...

Page 16: ...n the three screws on the side connect the U shaped interface cables in the order of brown blue and yellow green from left to right and then tighten the screws Step 8 Push the walk through metal detec...

Page 17: ...All rights reserved On Off 1 Before plugging in the power check whether the cables are properly connected and not loose 2 Connect the power plug of the console to 220V commercial power 3 Press the on...

Page 18: ...e zone indicators can be turned on or off If the metal detector detects metals of the size that reach or exceed the preset value the alarm indicator of the detection zone turns on and an alarm is gene...

Page 19: ...ideo duration face capture and display of binding measurement of human body temperature thermal imaging preview screen face capture and display of temperature measurement and high temperature alarm Wa...

Page 20: ...isplay the card number photo and name etc System Menu Bar 8 1 Click the menu bar to display the buttons for login registration password modification and user logout Login Enter the super administrator...

Page 21: ...Video Face Thermal Blocklist Identity System and About 1 WTMD You can set the alarm duration volume system channel overall sensitivity alarm mode system defense zone sensitivity of each area all sensi...

Page 22: ...ZK MD6000 Series User Manual and Installation Guide P a g e 21 Copyright 2022 ZKTECO CO LTD All rights reserved 2 Video Display the saved surveillance videos only load 30 at a time...

Page 23: ...Installation Guide P a g e 22 Copyright 2022 ZKTECO CO LTD All rights reserved Click the monitoring video after the loading is completed the first frame of the video will be displayed and then click...

Page 24: ...All rights reserved 3 Face Displays the measured temperature photos taken and time taken 4 Thermal Imaging Display all photos whose temperature is higher than the temperature set by the system and th...

Page 25: ...ueried 7 System Set the alarm temperature manual calibration temperature calibration value of the horizontal and vertical directions of the visible light and thermal imaging fusion and the alarm value...

Page 26: ...ZK MD6000 Series User Manual and Installation Guide P a g e 25 Copyright 2022 ZKTECO CO LTD All rights reserved...

Page 27: ...Android RAM 2GB ROM 2TB Monitor 29 inches Operating Temperature 10 C to 35 C Operating Environment Indoor Input Voltage 100V to 240V 50 60Hz WTMD Zones 33 Zones WTMD Working Frequency 5 7kHz to 9 6kH...

Page 28: ...l MCBF 2 Millions Certifications ISO9001 ISO 14001 CE FCC Arm Type One Drop Arm Arm Length 620mm Transparent Acrylic Board L W H 620mm 10mm 1098mm 2 PCS Detectable Gas CO CH2O H2 NH3 etc Capacity 30 0...

Page 29: ...6mm 2460mm 1730mm 1046mm 2460mm Entrance Control Dimension L W H 1730mm 1046mm 1350mm Dimensions with Packing L W H Package1 2550 720 458mm Door Panel Package 2 860 580 486mm Control Unit Package1 255...

Page 30: ...ranty Card 1 Please keep this card with reasonableness and show it when maintaining it 2 This card will be invalid if without the signature or stamp of the designated dealer 3 This card will be regard...

Page 31: ...Manual and Installation Guide P a g e 30 Copyright 2022 ZKTECO CO LTD All rights reserved Model Number ID Date Acquisition User Post Code Address User s Phone Number Fax Date of Maintenance Record of...

Page 32: ...2022 ZKTECO CO LTD All rights reserved ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD A...

Reviews: