X-Ray Inspection System
User Manual
P a g e
| 18
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
system
strip, dynamic scan, inverse image, etc.
Storage capacity
More than 100, 000 pictures
System functions
High density alert, drugs and explosives inspection,
date/time display, baggage counting, user
management, TIP, training and other functions.
Basic parameters of General series security inspection system
Model/Type
6550D
10080D
100100D
Dual energy
Dual energy
Dual energy
Basic
parameters
Channel
size
Width
(mm)
660
1004
1008
Height
(mm)
510
806
1005
Maximum evenly
distributed
load(kg)
180
200
200
Tube current(mA)
0.6 to 1.0
Anode voltage
140KV to 160KV
Cooling method
Sealed oil cold/100%
Environmental
Parameters
Storage
temperature/
relative humidity
-40±2
℃
to +60±2
℃
/5% to 95%(Not condensed)
Operating
temperature/relati
ve humidity
0±2
℃
to +40±2
℃
/5% to 95%(Not condensed)
Main Power
Supply
AC220V(-15% to +10%), 50Hz±3Hz