background image

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two  conditions:  (1) This  device  may  not  cause  harmful  interference,  and  (2) This  device 
must accept any interference received, including interference that may cause undesired 
operation.

This equipment has been tested and found to comply with the limits for a Class B digital 
device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide 
reasonable  protection  against  harmful  interference  in  a  residential  installation.  This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed 
and  used  in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio 
communications.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular  installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or 
television reception, which can be determined by turning the equipment off and on, the 
user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the  following 
measures:

IMPORTANT!

  Any  changes  or  modifications  not  expressly  approved  by  the  party 

responsible for compliance could void the user's authority to operate the equipment.

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Consult the dealer or an experienced radio/TV technician for help.

Warning: 

FCC RF Radiation Exposure Statement:

This Transmitter must not be co-located or operating in conjunction with any other 
antenna or transmitter. 

This  equipment  complies  with  RF  radiation  exposure  limits  set  forth  for  an 
uncontrolled environment.

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected.

Summary of Contents for ZL700

Page 1: ...Installation Guide Model ZL700 Lock Body America Standard Mortise with 5 Latches Version 1 0 English...

Page 2: ...are required Non alkaline and rechargeable batteries ARE NOT RECOMMENDED Do not remove the batteries when the lock is in working state When the battery power is low the lock will beep to remind the u...

Page 3: ...nstallation Procedure 2 1 Check Opening Direction 2 2 Drill Holes on the Door 3 3 Remove the Guide Plate 3 4 Installing Mortise 4 5 Installing Outdoor Unit 5 6 Installing Indoor Unit 6 7 Installing St...

Page 4: ...oor Unit Outdoor Unit Strike Plate and Box Spindle Hex Wrench Keys Vacuum Sucker Screw A Transfer Cable Note This type of lock is suitable for a door thickness of 36 mm to 55 mm If the door is thicker...

Page 5: ...Spindle A Cylinder Mortise Screw C Screw B Screw A Screw B Screw A Screw B Keys Transfer Cable Vacuum Sucker Outdoor Unit Door Strike Plate and Box Person Location Left Inward Right Inward Left Outwa...

Page 6: ...ste the Installation Template at the desired handle height Mark for the holes to be drilled and drill the marked places 1 2 3 Remove the Guide Plate Unscrew the Screw A and remove the Guide Plate 36 t...

Page 7: ...the drilled hole secure it with Screw B Make sure the Cylinder toward Outdoor Unit secure Cylinder with Screw C and Screw D by Hex Wrench A Secure the guide plate with Screw A make sure the cable tow...

Page 8: ...onnect 6 PIN end of Transfer Cable with Mortise cable Insert a Spindle A into the clutch toward Outdoor Unit Attach the Outdoor Unit to the door by connecting 8 PIN end of Transfer Cable with mainboar...

Page 9: ...talling Indoor Unit Insert another Spindle A into clutch toward Indoor Unit and insert the Spindle B into turn knob Secure the below of Indoor Unit with 2 Screw E 1 2 Spindle A Spindle B Screw E Hex W...

Page 10: ...e Battery Box and Indoor Unit with 2 Screw E 3 4 Screw E Hex Wrench B 7 Installing Strike Plate and Box Make sure that the Strike Box is aligned with the latch bolt Then use the Installation Template...

Page 11: ...ock by Mechanical Key Remove the cover on the key hole with the Vacuum Sucker Insert the key into the Cylinder and rotate it by 90 then rotate down the handle to open the door it means normal 1 2 Keys...

Page 12: ...Cerradura Hotelera de Est ndar Americano de 5 Pestillos Versi n 1 0 Modelo ZL700 Gu a de Instalaci n Espa ol...

Page 13: ...lcalinas AA no incluidas NO SE RECOMIENDAN pilas recargables y no alcalinas No quite las bater as cuando la cerradura est en funcionamiento Cuando la carga de la bater a es baja la cerradura emitir un...

Page 14: ...1 Direcci n de Apertura 2 2 Realice los Agujeros en la Puerta 3 3 Remueva la Placa Gu a 3 4 Instalaci n del Mortaja 4 5 Instalaci n de la Unidad Interior 5 6 Instalaci n de la Unidad Interior 6 7 Inst...

Page 15: ...dura no es apta para su proyecto Por favor contacte a suagende de ventas Contenido A B A B Unidad Exterior Unidad Interior Cilindro Caja de Bater as Mortaja Perno Cable de transferencia Placa de Caja...

Page 16: ...transferencia Llave Mec nica Llave Hex gonal A Tornillo D Perno B Perno A Llave Hex gonal B Tornillo E Unidad Interior Ventosa de Succin Perno A Tornillo E La puerta Bater as no incluidas Proceso de I...

Page 17: ...altura deseada de la manija Marque los agujeros a perforar y perfore los lugares marcados 1 2 3 Remueva la Placa Gu a Desatornille el tornillo D y retire la placa gu a 36 to 55 mm Realice los Agujero...

Page 18: ...Aseg rese de que el cilindro est orientado hacia la unidad exterior asegure el cilindro con el tornillo C y el tornillo D con la llave hex gonal A Asegure la placa gu a con el Tornillo A aseg rese de...

Page 19: ...e de transferencia con el cable de Mortaja Inserte un eje A en el embrague hacia la unidad exterior Fije la unidad exterior a la puerta conectando el extremo de 8 pines del cable de transferencia con...

Page 20: ...el embrague hacia la unidad interior e inserte el eje B en el pomo giratorio Asegure la parte inferior de la unidad interior con 2 tornillos E 1 2 Instalaci n de la Unidad Interior Perno A Tornillo E...

Page 21: ...de bater as y la unidad interior con 2 tornillos E 3 4 7 Instalaci n de la Placa de Contrachapa Asegrese de que la placa est alineada con el pestillo Luego use la plantilla de instalaci n para perfora...

Page 22: ...Mecanica Retire la tapa del ori cio de la cerradura con la ventosa de succin Inserte la llave en el orificio y grela 90 luego gire la manija hacia abajo para abrir la puerta lo que significa normal 1...

Page 23: ...not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment o and on the user is encoura...

Page 24: ...ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD All Rights Reserved...