CANFDNET-400U
High-Performance Four-Channel CANFD Bus-to-Ethernet Converter User Manual
©2021 Guangzhou ZLG Electronics Technology Co.,Ltd.
33
User Manual
Continued
Categ
ory
Name
Default
Description
IP
addre
ss
infor
matio
n
How to get an
IP address
Static
acquisition
(Static)
You can also select "Dynamic acquisition". Static
acquisition means that the user directly enters the "IP
address", "Subnet mask", and "Gateway". Dynamic
acquisition means that the CANENT-8E-U module uses
the DHCP protocol to obtain the IP address, subnet
mask and gateway information allocated by the DHCP
server on the network. Note: The function of dynamic
acquisition can only be used when there is a DHCP
server on the network. Usually, the router can also serve
as a DHCP server.
CAN
port
config
uratio
ns
Heartbeat time
(10 ms)
200
The values that can be filled are 0 and 100-65525. This
item is meaningful only when the TCP protocol is used
for communication. When the TCP connection is
established, a "heartbeat packet" (non-application data
will not be forwarded to the working port) will be sent
every time interval filled in this item. The CANET-8E-U
will disconnect the connection if the other party does not
respond to three consecutive heartbeat packets. If you
fill in "0", the "heartbeat packet" will not be sent.
CAN baud
rate (HEX)
1000K
There are 15 options from 5K to 1000K. You can also
enter any baud rate value yourself.
CAN working
mode
Normal
Normal: The CAN port can respond to the received CAN
frame properly;
Listen only: The CAN port works in listening mode and
does not respond;
Self-test: The CAN port works in self-transmitting and
self-receiving mode. This is used to check whether if it
can properly and whether it is damaged.