CANFDNET-400U
High-Performance Four-Channel CANFD Bus-to-Ethernet Converter User Manual
©2021 Guangzhou ZLG Electronics Technology Co.,Ltd.
3
User Manual
1.3 Specifications
1.3.1 LAN
100M/1000M Ethernet, RJ45 interface, 2 kV electromagnetic isolation.
1.3.2 CAN
Number of CAN ports: 8
Interface type: DB9 (male)
Signal cable: CAN0H-CAN0L, CAN7H-CAN7L
Baud rate: 5 k-1,000 kbps
1.3.3 Software Features
Supported TCP/IP protocols: ETHERNET, ARP, IP, ICMP, UDP, TCP, DHCP,
DNS
Communication software: CANtest test tool (V2.61), TCP/UDP test tool
Configuration software: ZNetCom (V3.33 or later)
1.3.4 EMC Characteristics
Interface
Test Item
Testing
Standards
Test
Voltage
Test
Result
Remarks
Power
interface
Electrostatic test
IEC61000-4-2
±6kV
A
Contact discharge
±8kV
Air discharge
Group pulse test
IEC61000-4-4
±2kV
A
Capacitive coupling
Surge test
IEC61000-4-5
±1kV
A
Differential mode
±2kV
A
Common mode
Ethernet
interface
Electrostatic test
IEC61000-4-2
±6kV
A
Contact discharge
±8kV
Air discharge
CAN
interface
Electrostatic test
IEC61000-4-2
±6kV
A
Contact discharge
±8kV
Air discharge
Group pulse test
IEC61000-4-4
±2kV
A
Capacitive coupling
clip
Surge test
IEC61000-4-5
±2kV
A
Common mode
Buttons,
indicators
Electrostatic test
IEC61000-4-2
±8kV
A
Air discharge
1.3.5 Electrical Parameters
Unless otherwise specified, the parameters listed in the following table refer to the
value at Tamb=25°C.
Parameter Name
Symbol
Rating
Unit
Power voltage
V
CC
+12
V
Power consumption
P
M
4000
mW