background image

 4

6

7

8

9

Slide chimney over the angle iron

s

 

and  place  in  position  on  top  of

 

the hood. Pull the electrical plug to 

the top of the chimney

.

Lift  the  hood  to  attach  the  angle 

iron

s

  to  the  ceiling  bracket.    Use 

screws pro-vided to attach.

 Chimney 

should be cut 2.5in short to allow 

for  screwing  angle  irons  into 

bracket.

Make

 

your  electrical  and

 

ducting connections. Use rigid duct 

wherever possible. Try and minimize 

the use of elbows. More elbows and 

longer  runs  create  higher  static 

pressure.  The  hood  comes  with  a 

grounded three prong plug that can 

either  be  direct

ly

  wired  or  plugged 

into a 20 amp circuit.

Slide 

crown  molding

  over  the 

crown  molding

  bracket  on  the 

ceiling

.

Remove plastic wrap from all sides 

and i

nstall stainless steel baffle 

filters.

Before installing baffle filters, make sure that you 

insert the grease cup under the motor blower.  

10

Reviews: