background image

The rating tag shows the model and serial number of your range. The tag is located 
under the front edge of the range cooktop.

Important Appliance Information

Dealer

Model

Date Installed

Installer

Location of Appliance Tags

Appliance Tag Here

Summary of Contents for RC-PBT-30

Page 1: ...Rangetops Cooktops Dropins Installation Guide and Users Manual ...

Page 2: ......

Page 3: ...hen needs these collections offer four to seven burners in various finishes sizes and BTUs Enjoy precise heat control through imported Italian burners combined with durable cast iron grills both known for their even heat distribution and longevity Made by hand and innovatively designed allowing exploration for the love of food ...

Page 4: ...SERVICE 3 BEFORE INSTALLATION 5 RANGETOP DROPIN INSTALL 8 INSTALLATION REQUIREMENTS 8 POWER RATING ELECTRICAL CONNECTION 9 WIRING SCHEMATICS 10 GAS CONNECTION 13 GAS CONVERSION PROCEDURE 17 INSTALLATION CHECKLIST 20 FINAL PREPARATION 20 Installation Guide ...

Page 5: ...CONTENTS Users Manual ROOM VENTILATION 22 COOKTOP COOKING 23 MAINTAINING YOUR RANGE 25 TROUBLESHOOTING 26 ...

Page 6: ...e leaves the factory after thorough quality inspection and testing Our distributors and our service partners are ready to answer any questions you may have regarding installation of your ZLINE product This manual will help you learn to use the product in the safest most efficient manner and care for it so that it may give you the highest satisfaction for years to come This manual also includes dir...

Page 7: ...s the model and serial number of your range The tag is located under the front edge of the range cooktop Important Appliance Information Dealer Model Date Installed Installer Location of Appliance Tags Appliance Tag Here ...

Page 8: ...uture reference The plug should always be accessible Installation must conform with local codes or in the absence of codes the National Fuel Gas Code NSIZ223 1 NFPA54 Electrical installation must be in accordance with the National electrical code ANSI NPA70 latest edition and or local codes In Canada Installation must be in accordance with the current CAN CGA fe 149 1 National gas installation cod...

Page 9: ...sol cans or combustibles Immediately call your gas supplier from a neighbor s phone follow the gas supplier s instructions In the case you cannot reach the gas supplier call the fire department Installation and service must be conducted by a qualified installer service agency or the gas supplier If the information in this manual is not followed exactly a fire or explosion may result causing proper...

Page 10: ...rvice on all products shall be carried out by industry professionals only For warranty service please call customer service Replacement Parts Only authorized replacement parts may be used in performing service on this appliance Replacement parts are available from ZLINE Call 1 614 777 5004 Warranty and Service ...

Page 11: ...4 Product Dimensions Dropins Cooktops Cooktop cut outs ...

Page 12: ...nce must be used with the pressure regulator provided The regulator must be properly installed in order to be accessible when the appliance is installed in its final location The pressure regulator must be set for the type of gas to be used The pressure regulator has 34 female pipe thread The appropriate fitting must be determined based on the size of your gas supply line the flexible metal connec...

Page 13: ...gas nozzles Gas Pressure The maximum inlet gas supply pressure incoming to the gas appliance pressure regulator is 34PSI 13 8w cpr 3 5kPA The minimum gas supply pressure for checking the regulator setting shall be at least 1 w c 249 Pa above the inlet specified manifold pressure to the appliance This operating pressure is 4 w c 1 00kPa for Natural gas and 1 1 w c 2 75 kPa for LP gas Before Install...

Page 14: ...e protective sealing strips along the edges of the opening in the bench top and carefully overlap the strip end See Fig 1 insert the dropin into the bench top opening With a screwdriver assemble the brackets A to the hotplate bottom by means of the screws B See Fig 2 Slide the hooks into position and secure them with the screws Trim the part of the sealing strips that extend beyond the dropin base...

Page 15: ...cy approved properly sized manual shut off valve should be installed no higher than 3 above the floor and no less than 2 and no more than 8 from the right side facing product To connect gas between shut off valve and regulator use agency approved properly sized flexible or rigid pipe Check all local code requirements Installation Adjacent to Kitchen Cabinets For the best look the worktop should be...

Page 16: ...ng 1 10 120 Vac 12A Max Electrical Grounding Our gas oven is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle Do not cut or remove the prong from this plug Disconnect electrical power at the circuit breaker box or fuse box before installing the appliance Provide appropriate ground for the appliance Use copp...

Page 17: ... 1 IGNITION ALLUMAGE SWITCH FOR ELECTRIC OVEN RA30 RAB30 RAS30 电路图 120 208 V Ac 60Hz 120 240 V Ac 60Hz WIRE CONNECTOR GREEN BROWN WHITE RED Heat pipes up INSIDE1800 2395 W OUTSIDE 650 865 W Heat pipes down 2000 2670W case fan RIGHT LAMP LIFT LAMP SWITCH FOR LAMP LIFT oven fan RIGHT oven fan SWITCH FOR THERMOSTAT SNAP THERMOSTAT SWITCH INDICATOR LIGHT IGNITION ALLUMAGE MICROSWITCH 1 MICROSWITCH 2 M...

Page 18: ... fan RIGHT LAMP LIFT LAMP SWITCH FOR LAMP Heat pipes up INSIDE1800 2395 W OUTSIDE 650 865 W Heat pipes down 2000 2670W LIFT oven fan RIGHT oven fan GROUND WIRE SWITCH FOR THERMOSTAT SNAP THERMOSTAT SWITCH MICROSWITCH 4 MICROSWITCH 3 MICROSWITCH 2 MICROSWITCH 1 IGNITION ALLUMAGE SWITCH FOR ELECTRIC OVEN RA30 RAB30 RAS30 电路图 ...

Page 19: ...ponsibility of the dealer and the owner of the range to perform the appropriate gas conversion following the directions of the manufacturer The gas conversion procedure is described in this manual and in the package containing the conversion nozzles shipped with every range Please provide the service person with this manual before work is started on the range Leak testing of the appliance shall be...

Page 20: ...e a heavy duty AGA design certified commercial flexible connector of at least 1 3cm IF NPT with a suitable strain relief in compliance with ANSI Z21 41 and Z21 69 standards In Massachusetts The unit must be installed with a 36 3 foot long flexible gas connector In Canada Use CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect device for use with gas fuel Pressure T...

Page 21: ...ral Gas 4 0 W c P L P Propane 10 0 W c P Incoming line pressure upstream from the regulator must be 1 W C P higher than the manifold pressure in order to check the regulator The regulator used on this range can withstand a maximum input pressure of PSI 13 8 W C or 3 5kPa If the line pressure exceeds that amount a step down regulator is required The appliance its individual shut off valve and the p...

Page 22: ...hed if all steps are not completed Before performing the gas conversion locate the package containing the replacement nozzles which has a number indicating its flow diameter printed on the body Consult the table below for matching nozzles to burners Save the nozzles removed from the range for future use LPG Liquid Propane Gas NG Natural Gas Propane Conversion Video ...

Page 23: ...16 Gas Connection procedure ...

Page 24: ...o operate with one of these gas pressure as indicated in the labels affixed on the appliance package and instruction booklet To convert the regulator for use with other liquid propane LP gas 1 Unscrew the upper cap of the regulator reverse its direction and screw it in firmly against the cap 2 Screw the metal cap by hand in the original position on the regulator Gas Conversion Procedure 5 8 R e v ...

Page 25: ...using a 7 mm socket wrench Replace nozzles using the conversion set supplied with the range Each nozzle has a number indicating its flow diameter printed on the body Consult the table on page 15 for matching nozzles to burners NG Natural Gas LPG Liquid Propane Gas NG LPG 9 32 9 32 Step1 Step 2 Step 3 Step 4 Step 5 Gas Conversion Procedure ...

Page 26: ... below and turn to the right or left until the burner flame is adjusted to desired minimum 4 Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position Gas Conversion Procedure 2 0 x 50 mm 2 0 x 50 mm Flame Adjustment The high flame setting cannot be adjusted to be lower If the height is too high revisit the conversion set up A step may have been misse...

Page 27: ...lue with no yellow tipping 8 Has the minimum setting for all burners been adjusted 9 Have the cooktop flames been adjusted to customer preference All stainless steel body parts should be wiped with hot soapy water and with a stainless steel cleanser If build up occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted material...

Page 28: ...21 Users Manual ...

Page 29: ...er ventilation in the room is needed Make sure the kitchen is equipped with a range hood of appropriate power 400 CFM minimum Activate the exhaust fan range hood when possible Intensive and continuous use of the appliance may require additional ventilation for example by opening a window Room Ventilation ...

Page 30: ...nob counter clockwise to the MAXIMUM position light the flame with a kitchen lighter or with a match Using the Burners Correctly 1 Always check that the burner caps are properly installed before operation 2 Verify that the flame of the worktop burners is completely blue and with a regular aspect as shown below 3 Always adjust the burner flame so it does not extend beyond the edge of the pan DO NOT...

Page 31: ...en igniting a burner all burners will spark but only the burner s knob you are using will ignite the flame OFF OFF OFF OFF Max 250 300 350 400 450 Symbols Oven Functions Selector COOKTOP COOKING Cooktop Functions Selector The flame color should always be blue Flickers of orange and yellow are acceptable If flames appear orange or yellow and stay that way check the surrounding area Candles cleaning...

Page 32: ...burner caps from the burner heads and wash them in a warm soap and water solution Dry thoroughly before using them again Before reinstalling them on the burner head check that the gas flow holes are not clogged with food residues or cleaning products Cleaning Enamel Enameled parts should be cleaned frequently with warm soap and water solution applied with a soft sponge or wipe Never use abrasive p...

Page 33: ... is interrupted Burner ports are clogged or the unit is not set to the appropriate gas type Call a technician to repair The air quality of the room is affecting the flame color Ensure that there are no candles cleaning products etc in the room Problem Range does not function Igniter does not work Igniter sparking taut no flame ignition Burner ignites but flame is large distorted or yellow ...

Page 34: ...Kitchen and Bath Three Locations 350 Parr Circle Reno NV 89512 916 Delaware Avenue Marysville OH 43040 319 Rowland Mill Road Bruceton TN 38317 www zlinekitchen com 1 614 777 5004 ...

Reviews: