13
INSTALLATION
ELECTRIC POWER RATING
A properly grounded and horizontally-mounted electrical NEMA 5-15 receptacle should
be installed no higher than 3" (76 mm) above the floor, and no less than 2" (51 mm) and not
more than 8" (203 mm) from the left side (facing product).
The appliance shall be connected to a single phase electric line rated at 120VAC and 60HZ.
The true voltage in most homes is usually within this rating.
ELECTRIC POWER RATING
120V / 60HZ / 15A
ELECTRICAL GROUNDING
Our gas range top is equipped with a three-prong plug for your protection against shock
hazard and should be plugged directly into a properly grounded receptacle. Do not cut or
remove the prong from this plug.
WARNING
Disconnect electrical power at the circuit breaker box or fuse box before
installing the appliance. Provide appropriate ground for the appliance. Use
copper conductors only.
Electrical Connection