INSTALLATION
STEP 1: PRESSURE REGULATOR
The pressure regulator supplied with the appliance is a convertible type pressure regulator
for use with natural gas at a nominal outlet pressure of 4" W.C.P. (1 kPa) or liquid propane
gas at a nominal outlet pressure of 10" W.C.P. (2.5 kPa) and it is pre-assembled from the
factory to operate with one of these gas pressures as indicated in the labels affixed on the
appliance, package, and instruction booklet.
To convert the regulator for use with other liquid propane gas:
1. Unscrew the front cap of the regulator (as seen below). Inside the cap is a screw. By
hand, remove the screw to reveal a spring. Invert the screw back into the cap with the
spring on top.
2. With the spring sticking out of the cap, reinstall the cap back onto the regulator.
3. Using a manometer, double check pressure is at 10" W.C.P. (2.5 kPa) If you need to
adjust pressure, screw or unscrew the black spacer where the spring is located.
Any issues related to improper liquid propane gas conversion are
NOT covered under warranty.