Pelletherm V.2 M01 22
5. ASSEMBLY AND INSTALLATION OF THE BOILER.
5.1. BASIC REQUIREMENTS FOR BOILER "PELLETHERM V.2 M01" INSTALLATION.
When assembling and installing hot-water pellet boiler series "Pelletherm V.2 M01", the
service technician must observe with the following basic requirements:
The room anticipated for the installation of the boiler must provide a constant flow of
fresh air needed for the combustion process and good ventilation;
It is not allowing installation of the boiler in dwellings, including corridors;
Joining the boiler to the heating installation must be performed only by a qualified
technician;
Installation and maintenance of solid fuel boilers is carried out by specialized
companies with right to perform this activity;
The hot-water pellet boiler "Pelletherm V.2 M01" is connected to the heating system
with
CLOSED
expansion vessel. In the event that the system is with closed
expansion vessel, in it must be installed pressure-relief valve that opens when
exceeding the operating pressure of the boiler (2.5 bar) and this valve must be
certified in accordance with PED 97/23;
Before entering the boiler into operation must there must be ensured complete filling
and venting the heating system.
Maintenance of the boiler should be performed only by adult persons who are
familiar with the operating instructions of the equipment.
5.2. INSTALLATION OF HOT-WATER BOILER "PELLETHERM V.2 M01".
The installation of the boiler requires preparation of and initial project in accordance with
applicable standards and regulations:
For the heating system - EN 303-5:2012 - "Heating boilers. Part 5: Heating boilers for
solid fuels, manually and automatically stoked nominal heat output of up to 500 kW.
Terminology, requirements, testing and marking;
For the chimney;
Fire safety requirements;
For the power supply - EN 60335-1/2006/A12012 - "Protection of domestic electrical
appliances".
When installing hot-water boiler series "Pelletherm V.2 M01" observe the
requirements for the necessary chimney draught referred to in the table with
the technical parameters of the boiler.
5.2.1. TRANSPORTATION OF BOILER "PELLETHERM V.2 M01".
Hot-water pellet boiler "Pelletherm V.2 M01" is available in packaged form (polyethylene and
stretch film), equipped and factory tested. Upon delivery, the boiler is situated vertically on
two wooden pallets.
On one pallet is situated and locked the main part of the equipment – boiler body (heat
exchanger) with mounted burner. On the other pallet is situated and locked fuel bunker and
screw feed (conveying) appliance.