Pelletherm V.2 M01 47
In case of emergency situation -
boiler overheating,
the emergency
thermostat is activated. There should be identified the cause for occurring of
this failure and to take appropriate measures for cooling of the boiler and
remove the failure. This thermostat must be reset manually by unscrewing the
protecting cap and press until the red button is switched (a clic must be clearly
heard), and then re-screw the cap. Also the boiler must be restarted by turning
off and turned on again with the switch "POWER".
Turning off the equipment is done by returning the switch "START" in initial position - "
off
".
This is the recommended way of turning off, as it is made the so called "
controlled
shutdown
", during which the concerned fans are running and emergency alarms are
observed. After cooling, the boiler must be switched off by switch "POWER", which is located
on the control panel of the equipment. It is also recommended equipment to be cleaned from
the ash accumulated.
6.6. MENU DISPLAYING A LIST OF LAST ERRORS DURING THE OPERATION OF THE
BOILER.
To check the last error occurred in the operation of boiler is necessary to use the menu "LOG".
In
LOG
menu are displayed as a list only the last 10 errors incurred in the
operation of the boiler. In case of occurring of a new error, the oldest will be
deleted and the newly occurred will be recorded.
Figure 6.17. On the display of the controller is displayed the selected menu "
LOG
" with the
error number and its code.
To exit the menu, press the button "ESC".
In Table 7.2 is given information on the error code and its explanation.
6.7. BOILER RESTART.
Restarting the boiler is necessary in situations in which the equipment has task to operate,
but the controller has changed to safe mode other than nominal under which it works at the
equipment and does not function. At the display is shown the code number of the message,
S
_
+
ESC
LOG error: 1: 22
EXIT
Error code