p. 61/69
convective part of the boiler is clogged, or in case that the flue gas duct is
not fully tightened and gas leaks are possible – it is highly recommended to
use personal protective breathing mask;
5.10.
Operation faults and their repairing
No
Operation fault
Cause
Method for repairing
It is necessary to increase the
frequency of fuel charging
and/or increase the amount of
fuel, charged
It is necessary to make
adjustment of the thermal
capacity of the boiler – see
5.3.7
Insufficient
heat
capacity of the boiler
Check the moisture content
of the wood log, eventually
replace the fuel with drier
one
Low
set-point
temperature
of
the
boiler’s
operating
thermostat
It is necessary to increase the
set-point of the boiler’s
operating thermostat (up to
90
o
C)
1.
Low
temperatures
in the heat supplied
rooms
Low
set-point
temperature
of
the
remote
room
thermostat
(if
connected)
It is necessary to increase the
set-point
of
the
room
thermostat
High
set-point
temperature
of
the
boiler’s
operating
thermostat
It is necessary to decrease the
set-point of the boiler’s
operating thermostat (it is
recommended to keep it
above 65
o
C)
High
set-point
temperature
of
the
remote
room
thermostat
(if
connected)
It is necessary to decrease the
set-point
of
the
room
thermostat
2.
High temperatures
in the heat supplied
rooms
High thermal capacity
of the boiler
It is necessary to decrease the
frequency of fuel charging
and/or decrease the amount
of fuel, charged