ECI3808 Network Motion Control Card User Manual V1.5
(4)
According to their respectively instructions, correctly set the relevant parameters of
the third-party equipment to match the parameters of each node.
(5)
When all is configured, it can start to do communicating.
(6)
Communication data of RS232 can be directly viewed through “ZDevelop / Controller
/ State the Controller / CommunicationInfo”.
3.4.
IN Digital Input & High-Speed Latch Port
The digital input adopts 4 groups of 10Pin screw-type pluggable terminals, and the
gap distance between terminals should be 5.08mm. In addition, the latch function and
encoder function are integrated in digital input signals.
→
Wiring Definition
Terminal
Name
Type
Function 1
Function 2
IN6
NPN leakage,
low-speed
input
Input 6
/
IN4
Input 4
/
IN2
Input 2
/
IN0
NPN leakage,
high-speed
input
Input 0
Latch A
IN26
NPN leakage,
low-speed
input
Input 26
IN24
Input 24
IN22
Input 22
Summary of Contents for ECI3808