ECI3828 Network Motion Control Card User Manual V1.5
POW
Status Indication
Led
1
Power indicator: it lights when power is conducted.
RUN
1
Run indicator: it lights when runs normally
ALM
1
Error indicator: it lights when runs abnormally
RS232
RS232 serial port
1
Use MODBUS_RTU protocol
RS422
RS422 serial port
1
Use MODBUS_RTU protocol
RS485
RS485 serial port
1
Use MODBUS_RTU protocol
EtherCAT
EtherCAT Bus
interface
1
EtherCAT bus interface, connect to EtherCAT bus
drive and EtherCAT bus expansion module.
ETHERNET
Net port
1
Use MODBUS_TCP protocol, expand Ethernet
through interchanger, the number of net port
channels can be checked through “?*port”, default IP
address id 192.168.0.11
E+24V
Main power
1
24V DC power supplies for controller
CAN
CAN bus interface
1
Connect CAN expansion module and CAN equipment
of other standards
IN
Digital IO input
24
NPN leakage type, power supplied by 24V, IN0-3
support latch function, IN-2, 21, 32 support encoder
function.
OUT
Digital IO output
16
NPN leakage type, power supplied by 24V, OUT0-1
support PWM function, OUT0-3 support hardware
comparison output function.
AD
Analog input
2
Resolution: 12 bits, 0-10V
DA
Analog output
2
Resolution: 12 bits, 0-10V
AXIS
Pulse axis
2
It includes differential pulse output and differential
encoder input
2.4.
Work Environment
Item
Parameters
Work Temperature
-10
℃
-55
℃
Work relative Humidity
10%-95% non-condensing
Storage Temperature
-40
℃
~
80
℃
(not frozen)
Storage Humidity
Below 90%RH (no frost)
Summary of Contents for ECI3828
Page 1: ......