ECI3828 Network Motion Control Card User Manual V1.5
⚫
Please connect a 120Ω
terminal resistor in parallel to each end of the CAN bus for
matching the circuit impedance and ensuring communication stability.
⚫
Please be sure to connect the public ends of each node on the CAN bus to prevent
the CAN chip from burning out.
⚫
Please use STP (Shielded Twisted Pair), especially in bad environments, and make
sure the shielding layer is fully grounded.
⚫
When on-site wiring, pay attention to make the distance between strong current and
weak current, it is recommended for the distance to be more than 20cm.
⚫
It should be noted that the equipment grounding (chassis) on the entire line must be
good, and the grounding of the chassis should be connected to the standard factory
ground pile.
→
Cable Requirements:
Shielded Twisted Pair, and the shielded cable is grounded.
3.2.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use ETHERNET, RS232 (default parameter, which can be
connected directly) or RS485 (default parameter, which can be connected directly, for
hardware, an adapter is needed) to connect to ZDevelop.
(3)
Please use “ADDRESS” and “SETCOM” command to set and view protocol station No.
Summary of Contents for ECI3828