ECI3828 Network Motion Control Card User Manual V1.5
→
Wiring Note:
⚫
For the connection of the public end, please connect the "EGND" port on the power
supply to the negative pole of the DC power supply of the external input device. If the
DC power supply of the external device and the controller power supply are in the
same power supply system, this connection can also be omitted.
⚫
E5V port is the output terminal of 5V power supply, this power terminal can be used
when input load of external 5V power supply needs to be provided, the maximum
current is 300mA.
3.5.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use ETHERNET, RS232 or RS485 to connect to ZDevelop.
(3)
Open or close output port directly through “OP” command, also, it can be opened or
closed through “ZDevelop/View/Op”. Please refer to “ZBasic” for details.
(4)
The PWM function, set the frequency and duty cycle through
“PWM_FREQ” and
“PWM_DUTY”. Please refer to ZBasic for details.
(5)
The hardware comparison output function
can be set through “HW_PSWITCH2”
instruction. Please refer to ZBasic for details.
Summary of Contents for ECI3828