ECI3828 Network Motion Control Card User Manual V1.5
3.6.
AD/DA: Analog Input / Output
The analog port adopts a set of 5Pin screw-type pluggable terminals with a spacing
of 5.08mm.
→
Wiring Definition
Terminal
Name
Type
Function
DA0
Output
Analog output terminal AOUT(0)
DA1
Analog output terminal AOUT(1)
AGND
Public end
Unique analog public end
AD0
Input
Analog input terminal AIN(0)
AD1
Analog input terminal AIN(1)
Note: ECI3828 inner AD and DA use internal power supply.
3.6.1.
Analog Input / Output Specification & Wiring
→
Specification
Item
AD
(
0-1
)
DA
(
0-1
)
Resolution
12-bit
12-bit
Data range
0-4095
0-4095
Signal range
0-10V input
0-10V output
Data refresh ratio
1KHz
1KHz
Load impedance
≤33KΩ
≥33KΩ
→
Wiring Reference
Summary of Contents for ECI3828
Page 1: ......