ECI3828 Network Motion Control Card User Manual V1.5
Isolation
cross skeleton
Connector
Crystal head with iron shell
Cable material
PVC
Cable length
Less than 100m
Use RJ45 network cable connection method:
⚫
When installing, hold the crystal head that is with the cable and insert it into the RJ45
interface until it makes a "click" sound (kada).
⚫
In order to ensure the stability of communication, please fix the cables with cable ties.
⚫
When disassembling, press the tail mechanism of the crystal head, and pull out the
connector and the module in a horizontal direction.
Please use tube-type pre-insulated terminals and cables with appropriate wire
diameters to connect the user terminals.
3.9.
Axis Interface
This product provides 2 local differential pulse axis interfaces, each interface is a
standard DB26 female socket. Each terminal provides 0V and +5V output, which can
provide 5V power for the encoder.
Before the axis is used, the use mode of the axis must be configured through the
ATYPE parameter.
→
Interface Definition
Interface
Pin
Signal
Description
1
EGND
Negative pole of 24V digital IO power
2
IN24-25/ALM
General input (recommended as driver alarm)
3
OUT16-17/ENBALE General output (recommended as driver enable)
4
EA-
Encoder differential input signal A-
5
EB-
Encoder differential input signal B-
6
EZ-
Encoder differential input signal Z-
7
+5V
5V power (+) of pulse/encoder signal
8
Reserved
Reserved
Summary of Contents for ECI3828
Page 1: ......