VPLCE532E Vision Motion Controller User Manual V1.5
(4)
Please use the "CANIO_ADDRESS" command to set the master's "address" and
"speed" according to the needs, and use the "CANIO_ENABLE" command to enable or
disable the internal CAN master function, or through "ZDevelop/Controller/State the
Controller/Communication
Info” to
view the CAN status intuitively, and refer to the
“ZBasic Programming Manual” for details
.
(5)
Please according to specific manual, set parameters related to the third party
equipment correctly to match each node’s parameters
.
(6)
Correctly set the "address" and "speed" of the slave station expansion module
according to the manual of the slave station.
(7)
After all the settings are completed, restart the power supply of all stations to
establish communication.
(8)
Note that the "speed" settings of each node on the CAN bus must be consistent, and
the "address" settings cannot cause conflicts, otherwise the "ALM" alarm light will be
on, and the communication establishment will fail or the communication will be
disordered.