VPLCE532E Vision Motion Controller User Manual V1.5
12
Reserved
Reserved
13
GND
Negative pole of 5V power of
pulse/encoder signal
14
OVCC
Positive pole of IO 24V power
15
OUT18-
23/CLR
Digital output, recommended to
clear driver alarm
16
IN30-35/INP
Digital input, recommended as
position on-site signal
17
EA+
Encoder differential input signal A+
18
EB+
Encoder differential input signal B+
19
EZ+
Encoder differential input signal Z+
20
GND
Negative pole of 5V power of
pulse/encoder signal
21
GND
22
DIR-
Servo or step direction output -
(differential signal)
23
PUL+
Servo or step pulse
(differential signal)
24
GND
Negative pole of 5V power of
pulse/encoder signal
25
Reserved
Reserved
26
Reserved
Reserved
Note:
ENABLE and CLR are recommended to be used as axis IO, because the drive
capacity is small.
OVCC, +5V are only used for communication between the controller and the
servo driver, please do not use it as power supply for other places.
3.11.1.
AXIS Interface Signal Specification & Wiring
→
Specification:
Signal
Item
Description
PUL/DIR
Signal type
Differential output signal
Voltage range
0-5V
Maximum frequency
10MHz