Cable Requirements:
Shielded Twisted Pair, and the shielded cable is grounded.
3.1.3.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use ETHERNET or RS232 to connect to ZDevelop.
(3)
Please use the "CANIO_ADDRESS" command to set the master's "address" and
"speed" according to the needs, and use the "CANIO_ENABLE" command to enable or
disable the internal CAN master function, or through "ZDevelop/Controller/State the
Controller/Communication
Info” to
view the CAN status intuitively, and refer to the
“ZBasic Programming Manual” for details
.
(4)
Correctly set the "address" and "speed" of the slave station expansion module
according to the manual of the slave station.