ZMC004WEA Motion Controller User Manual V1.5
(4)
Latch function can be set and triggered
through “REGIST” instruction, in software,
use REG_INPUTS to configure. Please refe
r to “ZBasic” for details.
3.5.
OUT Digital Output, Single-ended Pulse
The digital output adopts 2 sets of screw-type pluggable terminals with a spacing of
5.08mm, and the PWM function is integrated in digital output signal.
→
Terminal Definition
Terminal
Name
Type
Function 1
Function 2
EGND
/
E24V power ground / IO
public end
/
E5V
/
IO power input, E24V
/
OUT0
NPN Leakage
type, low-
speed output
Output 0
/
OUT1
Output 1
/
OUT2
Output 2
/
OUT3
Output 3
/
OUT4
Output 4
/
OUT5
Output 5
/
OUT6
Output 6
/
OUT7
Output 7
/
EGND
/
E5V power ground / IO
public end
/
E5V
/
E5V power ground, max
is 300mA
/
OUT8
NPN Leakage
type, high-
speed output
Output 8
DIR3
OUT9
Output 9
PUL3
OUT10
Output 10
DIR2
OUT11
Output 11
PUL2
OUT12
Output 12
DIR1
OUT13
Output 13
PUL1
OUT14
Output 14
DIR0