ZMC004WEA Motion Controller User Manual V1.5
3.6.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use any one interface among the three interfaces ETHERNET,
RS232 and RS485 to connect to ZDevelop.
(3)
Analog input voltage can be read through “AIN” command and corresponding analog
voltage can be output
through “
AOUT
” command, also,
data of each channel can be
checked
through “ZDevelop/
View/AD/DA
”. Please refer to “ZBasic” for
details.
3.7.
EtherCAT Bus Interface / Ethernet
ZMC004WEA motion controller has a 100M EtherCAT communication interface, and
it supports EtherCAT protocol. In addition, EtherCAT driver or EtherCAT expansion module
can be connected. Also, it can be ethernet to communicate with host computer, and
supports MODBUS_TCP protocol and custom communication. The default IP address is
192.168.0.11. The pin definition is as follows:
Summary of Contents for ZMC004WEA
Page 1: ......