ZMC004WEA Motion Controller User Manual V1.5
3.3.2.
Basic Usage
(1)
Please follow the above wiring instructions for correct wiring.
(2)
After powered on, please use any one interface among the three interfaces ETHERNET,
RS232 (there is default parameter, which can be connected directly) and RS485 (there
is default parameter, which can be connected directly, but for hardware, adapter head
is needed) to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station number and configured parameters, see "ZBasic Programming Manual" for
details.
(4)
According to their respectively instructions, correctly set the relevant parameters of
the third-party equipment to match the parameters of each node.
(5)
When all is configured, it can start to do communicating.
(6)
Communication data of RS232 / RS485 can be directly viewed through
“ZDevelop /
Controller / State the Controller / CommunicationInfo”.