ZMC004WEA Motion Controller User Manual V1.5
→
Wiring Note:
⚫
The wiring principle of high-speed digital input IN (14-15) and low-speed digital input
IN (0-13) is shown in the figure above. The external signal source can be an
optocoupler, a key switch or a sensor, etc., all can be connected as long as the
requirements on output of electric level can be achieved.
⚫
For the public end, please connect the "EGND" port on the IO power supply to the
"COM" terminal of the external input device. If the signal area power supply of the
external device and the power supply of the controller are in the same power supply
system, this connection also can be omitted.
3.4.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please select any one interface among the three interfaces
ETHERNET, RS232 and RS485 to connect to ZDevelop.
(3)
State values of relative input ports
can be read directly through “IN” command, also,
it can be read through “ZDevelop/View/In”. Please refer to “ZBasic” for details.
Summary of Contents for ZMC004WEA
Page 1: ......