ZMC006CE Motion Controller User Manual V1.5
3.10.
AXIS Differential Pulse Axis Interface
This product provides 6 local differential pulse axis interfaces, each interface is a
standard DB9 female socket.
→
Interface Definition
Interface
Pin
Signal
Description
1
PUL+
Servo/step pulse output differential
2
PUL-
Servo/step pulse output differential signal -
3
DIR+
Servo/step directional output differential
4
DIR--
Servo/step directional output differential signal -
5
GND
Pulse/encoder signal 5V power negative pole
6
IN24-
29/ALM
Digital input, recommended to do drive alarm
7
OUT8-
13/ENA
Digital output, recommended to do drive enable
8
+5V
Pulse/encoder signal 5V power positive pole
9
EGND
Digital IO power 24V negative pole
Note:
ALM and ENA are recommended to be used as axis IO due to their small drive
capacity.
+5V is only used for communication between the controller and the servo driver,
please do not use it as power supply for other places.