ZMC006CE Motion Controller User Manual V1.5
3.10.1.
AXIS Interface Signal Specification & Wiring
→
Specification:
Signal
Item
Description
PUL/DIR
Signal type
Differential output signal
Signal voltage range
0-5V
Signal max frequency
10MHz
IN24-29
Input method
NPN leak type, low electric level
input trigger
Input frequency
<
5kHz
Input impedance
6.8KΩ
Input voltage level
DC24V
Input opening voltage
<10.5V
Input closing voltage
>10.7V
Min input current
-1.8mA
Max input current
-4mA
Isolation
Optical isolation
OUT8-13
Output method
NPN leak type, 0V when outputs
Output frequency
<
8kHz
Output voltage level
DC24V
Max output current
+50mA
Overcurrent protection
No
Isolation
Optical isolation
+5V
,
GND
5V power max output current
50mA
EGND
24V power max output current
50mA
→
Wiring Reference:
Reference example of wiring with Panasonic A5/A6 servo driver:
Summary of Contents for ZMC006CE