ZMC212BE Motion Controller User Manual V1.5
Notes:
➢
The wiring principle of the encoder interface is as shown in the figure above. There
are differences in the wiring methods of different models of drivers, so please
connect with caution.
➢
Please use twisted-pair shielded wires, especially in harsh environments. Make sure
the shielding layer is fully grounded.
3.11.
AXIS Differential Pulse Axis Interface
This product provides 12 local differential pulse axis interfaces, and they integrate in
six 16pin horn connector male seats.
Before using, please configure axis type through ATYPE parameter.
Summary of Contents for ZMC212BE
Page 1: ......