ZMC303 Motion Controller User Manual V1.5
is needed) to connect to ZDevelop.
(3)
Please use the "ADDRESS" and "SETCOM" commands to set and view the protocol
station number and configured parameters, see "ZBasic Programming Manual" for
details.
(4)
According to their respectively instructions, correctly set the relevant parameters of
the third-party equipment to match the parameters of each node.
(5)
When all is configured, it can start to do communicating.
(6)
Communication data of RS232 / RS485 can be directly viewed through “ZDevelop /
Controller / State the Controller / CommunicationInfo”.
3.4.
IN Digital Input & High-Speed Latch Port
The digital input adopts 3 groups of 10Pin (there are 3 groups of 10 terminals) screw-
type pluggable terminals, and the gap distance between terminals should be 3.81mm. In
addition, the high-speed latch function and single-ended encoder functions are
integrated in digital input signals.
Summary of Contents for ZMC303
Page 1: ......