ZMC306X Motion Controller User Manual V1.5
⚫
For the public end, please connect the "EGND" port on the power supply to the "COM"
terminal of the external input device. If the signal area power supply of the external
device and the power supply of the controller are in the same power supply system,
this connection also can be omitted.
3.4.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please select any one interface among the three interfaces
ETHERNET, RS232 and RS485 to connect to ZDevelop.
(3)
State values of relative input ports
can be read directly through “IN” command, also,
it can be read through “ZDevelop/View/In”. Please refer to “ZBasic” for details.
(4)
Latch function can be set and triggered
through “REGIST” instruction, in software,
use REG_INPUTS to configure. Please refer to “ZBasic” for details.
3.5.
OUT (Digital Output, PWM Terminal)
The digital output adopts 2 groups of screw-type pluggable terminals with a spacing
of 3.81mm, and the PWM is integrated in digital output signals.
Summary of Contents for ZMC306X
Page 1: ......