ZMC308BE Motion Controller Hardware Manual V1.5
Isolation
cross skeleton
Connector
Crystal head with iron shell
Cable material
PVC
Cable length
Less than 100m
Use RJ45 network cable connection method:
⚫
When installing, hold the crystal head with the cable and insert it into the RJ45
interface until it makes a "click" sound (kada).
⚫
In order to ensure the stability of communication, please fix the cables with cable ties.
⚫
When disassembling, press the tail mechanism of the crystal head and pull out the
connector and the module in a horizontal direction.
Please use tube-type pre-insulated terminals and cables with appropriate wire
diameters to connect the user terminals.
3.10.
AXIS Differential Pulse Axis Interface
This product provides 8 local differential pulse axis interfaces, each interface is a
standard DB25 female socket. Each terminal provides 0V and +5V output, which can
provide 5V power for the encoder.
Before the axis is used, the use mode of the axis must be configured through the
ATYPE parameter.
→
Interface Definition
Interface
Pin
Signal
Description
1
EGND
Digital IO power 24V negative pole
2
IN40-47/ALM
Digital input, it is recommended to
do drive alarm
3
OUT16.18.20.2
2.24.26.28.30/
ENABLE
Digital output, it is recommended
to do drive enable
4
EA-
Encoder differential input signal A-
5
EB-
Encoder differential input signal B-