ZMC308BE Motion Controller Hardware Manual V1.5
6
EZ-
Encoder differential input signal Z-
7
+5V
Pulse/encoder signal 5V power
supply positive pole
8
Reserved
Hang in the air
9
DIR+
Servo or step direction output
differential
10
GND
Pulse/encoder signal 5V power
supply negative
11
PUL-
Servo or step pulse output
differential signal-
12
Reserved
Hang in the air
13
GND
Pulse/encoder signal 5V power
supply negative
14
OVCC
Digital IO power 24V positive pole
15
OUT17.19.21.2
3.25.27.29.31/
CIR
Digital output, it is recommended
to do drive alarm clear
16
IN48-55/INP
General input, it is recommended to
do on-position signal
17
EA+
Encoder differential input signal A+
18
EB+
Encoder differential input signal B+
19
EZ+
Encoder differential input signal Z+
20
GND
Pulse/encoder signal 5V power
supply negative pole
21
GND
22
DIR-
Servo or step direction output
differential signal-
23
PUL+
Servo or step direction output
differential
24
GND
Pulse/encoder signal 5V power
supply negative pole
25
Reserved
Hang in the air
Note:
ALM, ENABLE, CLR and INP are recommended to be used as axis IO due to their
small drive capacity.