ZMC408SCAN Motion Controller Hardware Manual V1.5
3.4.
AD/DA Analog Input/Output
The analog port adopts a set of 5Pin screw-type pluggable terminals with a spacing
of 3.81mm.
→
Terminal Definition
Terminal
Name
Type
Function
AD0
Input
Analog input terminal: AIN(0)
AD1
Analog input terminal: AIN(1)
AGND
Public End
Public end of this analog
DA0
Output
Analog output terminal: AOUT(0)
DA1
Analog output terminal: AOUT(1)
3.4.1.
AD/DA Analog Input/Output Specification & Wiring
→
Specification
Item
AD
(
0-1
)
DA
(
0-1
)
Resolution
12-bit
12-bit
Data range
0-4095
0-4095
Signal range
0-10V input
0-10V output
Data refresh ratio
1KHz
1KHz
Load impedance
≥33KΩ
≤33KΩ
→
Wiring Reference