ZMC408SCAN Motion Controller Hardware Manual V1.5
20
Power ON
IN48
Laser system input when powered on,
24V is valid
21
Laser standby
IN47
Laser input when in standby status, 24V
is valid
22
Ready
IN46
Laser is in ready status to input, 24V is
valid
23,25
EGND
EGND
Reference ground of each digital input
and output
24
Mod
OUT8
Modulation , 24V electric level
Attention:
1.
Except PWM and Modulation, other signals of inputs and outputs in above form all support
customization.
2.
AIN (2) and AOUT (2) are reserved signals, but standard models don’t have, please select special
mode when ordering if you need.
5.1.
LASER Interface Specification & Wiring
→
Specification
Signal
Item
Parameter
OUT (28-33)
Output method
Source type
Output frequency
<8kHz
Max output voltage
24V
Min output voltage
0V
Normal voltage
0V
Max output current
8mA
Overcurrent protection
NO
Isolation method
Optoelectrical isolation
OUT (8-9)
Output method
Push-pull output
Output frequency
Recommendation: <1MHz
Max output voltage
24V
Min output voltage
0V
Normal voltage
24V
Max output current
+_50mA