ZMC408SCAN Motion Controller Hardware Manual V1.5
12
NC
Reserved
/
13
NC
Reserved
/
14,15
GND
Negative pole of +5V output, signal
public end
/
16
STA0
Alarm status feedback (input interface)
IN66 (EXIO_10)
17
+5V
+5V output positive pole, max is
100mA, hang in the air when no use
/
18
M0
Main oscillator switch signal
OUT47 (EXIO_7)
19
GATE
5V PWM laser modulation signal
OUT48 (EXIO_9)
20
PRR
5V PWM laser frequency signal
OUT9 (EXIO_2)
21
STA1
Alarm status feedback (input interface)
IN67 (EXIO_0)
22
RED
LIAGHT
Red light signal
OUT48 (EXIO_14)
23
EMSTOP
Emergency stop signal
OUT49 (EXIO_15)
24,25
NC
Reserved
/
→
Specification
Item
IN (66-68)
Item
OUT (8-9, 36-43, 46-49)
Input
method
Leakage type, it is triggered
by low electricity
Output
method
0-5V TTL output
Input
frequency
Recommendation: <5kHz
Output
frequency
Max 10Mbps
Input
impedance
4.7KΩ
Max output
voltage
4.9V
Voltage to
ON
<2.9V
Min output
voltage
0.1V
Voltage to
OFF
>3V
Initial logic
0
Min input
current
1.8mA
Max output
current
± 20mA
Max input
current
8.1mA
Overcurrent
protection
NO
Isolation
NO
Isolation
NO
+5V max output current
100mA