ZMC408SCAN Motion Controller Hardware Manual V1.5
→
Wiring Notes
Above is the example of MFPT-200P, also, you can refer this to customize the specific
pin to be connected.
Please use the cable with shield, and shield layer should be connected to the ground
fully (chassis).
The FIBER laser uses the EXIO extended IO interface and matches with (connects to) the
FIBER adapter board to control. The laser control reference steps are as follows:
1.
Laser type setting: call the command EXIO_DIR(0, $8FFFF) to set the EXIO laser type
to FIBER type.
2.
Laser power setting: call the command AOUT to operate DA(3) and modify the value
range of D0-D7 from 0-255 to correspond to the laser power of 0-100%. The value of DA(3)
also corresponds to the state of the output ports OUT36-OUT43 bit by bit.
3.
Turn on the laser: call the command MOVE_OP to operate OUT47 to turn on the laser
enable, and call the command MOVE_OP to operate OUT(8) after a delay of 5ms to turn
on the laser.
4.
Laser red light: call the command MOVE_OP to operate OUT(48) to turn on the red
light.
5.
Laser PWM power setting: call the command PWM_FREQ to operate PWM9 to set the
output frequency of the PRR signal, and call the command PWM_DUTY to operate PWM9
to set the duty cycle of the PRR signal.
Note: for terminal control, please refer to laser manual description.
6.2.2.
YAG Laser Adapter Board
ZMC408SCAN-YAG adapter board is below, output port adopts DB25 male socket,
which can be used connect to UW-YAG types lasers.