ZMC412 Motion Controller User Manual V1.5
(4)
Correctly set the relevant parameters of the third-party equipment according to their
respective instructions to match the parameters of each node.
(5)
When all is configured, it can start to do communicating.
(6)
Communication data of RS232 / RS485 can be directly viewed through
“ZDevelop /
Controller / State the Controller / CommunicationInfo”.
3.4.
IN Digital Input & High-Speed Latch Port
The digital input adopts 3 groups of 10Pin screw-type pluggable terminals with a
pitch of 3.81mm, and the digital input signal integrates the high-speed latch function.
→
Wiring Definition
Terminal
Name
Type
Function 1
Function 2
EGND
/
External power
ground
/
EGND
/
/
IN0
NPN leakage type,
high-speed input
Input 0
High Speed
Latch
IN1
Input 1
IN2
Input 2
IN3
Input 3
IN4
Input 4
IN5
Input 5
IN6
Input 6
IN7
Input 7
Summary of Contents for ZMC412
Page 1: ......