ZMC416BE Motion Controller User Manual V1.5
connect carefully.
Please use twisted-pair shielded cables, especially in harsh environments, and make
sure the shielding layer is fully grounded.
3.11.2.
Basic Usage
(1)
Please follow the above wiring instructions for correct wiring.
(2)
After power on, please use any of the three interfaces ETHERNET, RS232 (default
parameter, it can be connected directly) and RS485 (default parameter can be
connected directly, one adapter is needed for hardware) to connect to ZDevelop.
(3)
Set axis parameters, such as, ATYPE, UNITS, SPEED, ACCEL, FWD_IN, REV_IN, etc.
(4)
There are many parameters related to pulse axis, they can be set and checked
through relative instructions, please see “axis parameter and axis status” of “ZBasic”,
or see “ZDevelop/View/Axis parameter”.
(5)
Control corresponding motion through “View –
Manual”.