ZMC420SCAN Motion Controller
22
4
GND
Internal power
ground
2.2.8
Axis interface signal:
provided 0V and + 5V output, can provide 5V
power supply for the encoder. Before the axis
is used, the use of the axis must be
configured through the ATYPE parameter.
Pin
number
sign
al
Expl
anat
ion
1
EGND
External power ground
2
IN24-29 / ALM
Universal input, it is
recommended to drive alarm
3
OUT12-17 / ENABLE
General output, it is
recommended to enable the
drive
4
EA-
Encoder input
5
EB-
Encoder input
6
EZ-
Encoder input
7
+ 5V
Internal power 5v
output
8
spare
spare
9
DIR +
Servo or step direction
output
10
GND
Internal power ground
11
PUL-
Servo or step pulse output
12
spare
spare
13
GND
Internal power ground