ZMC420SCAN Motion Controller
29
Pin
number
sign
al
Expl
anat
ion
1
CLOCK-
Clock signal
2
SYNC-
Sync signal-
3
Xchannel-
Galvanometer X channel signal-
4
Ychannel-
Galvanometer Y channel signal-
5
NC
Keep
6
STATUS-
Galvanometer status signal-
7
NC
Keep
8
GND
Digitally
9
CLOCK +
Clock
10
SYNC +
Sync
11
Xc
Galvanometer X channel
12
Yc
Galvanometer Y channel
13
NC
Keep
14
Galvanometer status
15
GND
Digitally
Local axis number 4/5 can be configured as the first galvanometer with ATYPE
= 21; local axis number 6/7 can be configured as the second galvanometer with
ATYPE = 21, and the axis number can be changed through AXIS_ADDRESS
configuration.
2.3
RTEX drive settings
The default firmware configuration of the controller is 0.5ms, and the corresponding
drive configuration is:
7.20
RTEX communication
cycle
3
0.5ms
7.21
RTEX instruction
update cycle
1
0.5ms
If the controller firmware cycle is 1ms, the corresponding configuration is:
7.20
RTEX communication
cycle
6
1ms
7.21
RTEX instruction
update cycle
1
1ms