The electrical characteristics are within
±
3 percent of the indicated values of Isc, Voc and Pmpp
under test conditions (irradiance of 1000W/cm
2
,AM1.5 spectrum, and a cell temperature of 25
℃
)
●
Under normal conditions, a photovoltaic module is likely to experience conditions that produce
more current and/or voltage than reported at standard test conditions. Accordingly, the values of ISC and
VOC marked on this module should be multiplied by a factor of 1,25when determining component voltage
ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output."
●
Installation should be in accordance with Australian installation standards AS3000 wiring rules and
AS/NZS 5033.
2、
Operating environment
CLIMATE CONDITION
Install the PV module in the following conditions:
●
Environment temperature
:
-20
℃
to 40
℃。
●
Operating temperature
:
-40
℃
to 80
℃。
●
Waterproof: don’t dip the modules into the water or continually explode under the water device
or fountain.
●
Antisepsis: keep away from salt erode and sulfuration places
●
Do not wear rings, jewelry, watches or other metallic items while working with photov
oltaic modules.
3、
Mounting and notes
●
The modules’ electrical performance in a system is the same. When connected in series, all
modules must have the same amperage. When connected in parallel, the modules must all have
the same voltage. Connect the quantity of modules that match the voltage specifications of the
devices used in the system. The modules must not be connected together to create a voltage that
is higher than the permitted system voltage.
●
To minimize risk in the event of an indirect lightning strike, avoid forming loops when designing
the system.