  Mounting Manual 

INSTALLATION INSTRUCTION FOR SINGLE GLASS SOLAR MODULE 

  S

ingle glass solar modules are made of 120/132/144/pcs of 158.75mm

×79

.375mm crystalline solar cells in 

series with high efficiency, high transmission and low iron toughened glasses , anti-aging EVA and high flame-

resistant back sheet to laminate, and anodized aluminum alloy frame. Products have high efficiency, lifespan 

easy installation, high wind resistance etc. 

Products are made according to international standard IEC61215-2016; IEC61730-2016 and have passed 

authority test center’s examination. Our products can be used in home roof solar systems, PV stations, 

communication stations, petrol, ocean, meteorological, traffic and solar building etc. 

Information for installers 

Installers must read and understand this manual before installation. 

Please ensure that installation, operation and maintenance of your photovoltaic system is only carried 

out by qualified persons able to carry out the technical procedures described in this manual, i.e. system planers, 

installers and maintenance personnel, and is carried out in accordance with all safety precautions in this manual 

and any and all applicable local codes. If you do not possess these qualifications, you may not carry out the work 

described herein except for cleaning. 

This manual and the instructions set forth herein are part of the product and should therefore be kept for 

the entire useful life of the solar installation. 

Information for operators 

Keep these instructions safe for the entire useful life of the solar installation. 

Please contact your plant supplier for information concerning the formal requirements for solar systems. 

Please be sure to learn about directives and permit requirements from the responsible local authorities and 

energy providers prior to installation of the solar plant. 

We recommend that you insure your solar system against natural hazards (e.g. against lightning strikes). 

 
 
 
 
 
 

Summary of Contents for ZXM6-H120

Page 1: ...ion operation and maintenance of your photovoltaic system is only carried out by qualified persons able to carry out the technical procedures described in this manual i e system planers installers and maintenance personnel and is carried out in accordance with all safety precautions in this manual and any and all applicable local codes If you do not possess these qualifications you may not carry o...

Page 2: ...6 H120 ZXP6 H120 Max series fuse rating A 15 Nominal Mass 22 5kg 21 5kg 21kg 20 5kg 20 5kg 19 5kg Package Size mm 2000x992x40 35 2024x1002x40 35 2020x1002x40 35 2040x1002x40 35 1844x992x40 35 1860x1002x40 35 1675x992x40 35 1696x1002x40 35 Cell Size mm 158 75x79 375 156 75x78 37 MAX System voltage DC1500V Application class Class A ...

Page 3: ...aces If there is exposure to salt i e marine environment and sulfur i e sulfur sources volcanoes there is a risk of corrosion It s not recommended to install the modules when the distance is less than 100m and it s recommended to install the modules with the anti salt function when the distance is between 100m and 1km Do not wear rings jewelry watches or other metallic items while working with pho...

Page 4: ...ons where the solar modules are mounted to a permanent structure the solar modules should be tilted for optimum winter performance As a rule if the system power output is adequate in the winter it will be satisfactory during the rest of the year The module tilt angle is measured between the solar modules and the ground Avoid installing under the shadow even the module factory use the bypass diode ...

Page 5: ...the bolt and the bolt must be put through the hole fixed in the aluminum frame 3 Use the nut and cut washer to fix all the parts The copper wire can not be attached to the aluminum Do not interrupt or influence the conductive connection when making daily maintenance All the crunodes on the conductive connection must be fixed The fastness does not depend on soldering 5 Suggested maximum number of m...

Page 6: ...o secure the modules to support structure Always use all the eight mounting holes to secure the modules The module installed with screws on the front frame for load see the following picture and refer to the following table Mechanical load pressure Installation direction 3600Pa 1600Pa with safety factor 1 5 ...

Page 7: ...t can run off freely to avoid standing water or pudding This resistance value can decrease if modules are not mounted following the instructions above B Clamping installation Only for frame with 40mm thickness Modules can be installed with clamps Modules must be securely attached to the mounting structure with four clamps on the long frame The modules must be properly secured to their support so t...

Page 8: ... just for reference Customer can select the corresponding installation manual based on the purchased module 7 Wiring The modules use thePV JX1203 type junction box This box on the back side of the module is weatherproof and is designed to be used with standard wiring or conduit connections Wiring methods should be in accordance with the NEC National Electrical Code Bypass diodes and cable clamps a...

Page 9: ...hoose the control box with LJQ 1 LJQ 3 type Connectors 8 Maintenance and cleaning Do not change the PV components optionally diode junction box plug connectors Given a sufficient tilt at least 15 it is not generally necessary to clean the modules rainfall will have a self cleaning effect In case of heavy soiling which will result in output reductions we recommend cleaning the modules using plenty ...

Page 10: ...wiring and the inverter Be sure carefully to follow manufacture s installation instructions Artificially concentrated sunlight shall not be directed on the modules or panels 11 Danger of death from arcing Modules generate direct current when light shines on them An arc may be produced when connections are separated We therefore recommend covering modules with a lightproof cloth during installation...

Page 11: ...o panels doped with gallium coated glass 第 11 12 位数字码 第 9 10 位数字码 第 6 位数字码 第 7 8 位数字码 第 5 位数字码 第 3 位数字码 第 4 位数字码 第 1 2 位数字码 PV modules were manufactured by ZNshine ZNSHINE PV TECH Co Ltd No 1 South Zhenxing Road Industrial Zone Zhixi Town Jintan District Changzhou City Jiangsu Province China Not free from PID Free from PID one number 0 represents for 3BB modules which are not free from PID 1 repre...

Page 12: ...0 405 最大功率点的工作电压 Max Power Voltage Vmp V 40 6 40 8 41 41 2 最大功率点的工作电流 Max Power Current Imp A 9 61 9 69 9 76 9 84 开路电压 Open Circuit Voltage Voc V 48 7 48 9 49 1 49 3 开路电流 Short Circuit Current Isc A 10 08 10 16 10 24 10 32 组件系列 Module Series 132pcs 158 75 158 75mm Monocrystalline Silicon Module 尺寸 mm 重量 kg Dimensions mm Weight kg 1860 1002 40 35 系统电压 VDC Max System Voltage VDC 1500 最大保险丝额定电流 A Max...

Page 13: ...Electrical Performance STC 组件类型 Model Type ZXM6 H120 315 M ZXM6 H120 330 M 最大功率 Max Power Pm W 315 330 最大功率点的工作电压 Max Power Voltage Vmp V 33 2 33 8 最大功率点的工作电流 Max Power Current Imp A 9 49 9 77 开路电压 Open Circuit Voltage Voc V 40 40 6 开路电流 Short Circuit Current Isc A 10 10 3 组件系列 Module Series 132pcs 156 75 156 75mm Polycrystalline Silicon Module 尺寸 mm 重量 kg Dimensions mm Weight kg 1844 992 40 35 系统...

Page 14: ... Dimensions mm Weight kg 1675x992x40 35 系统电压 VDC Max System Voltage VDC 1500 最大保险丝额定电流 A Max Series Fuse A 15 电气参数 标准测试条件下 Electrical Performance STC 组件类型 Model Type ZXP6 H120 300 P 最大功率 Max Power Pm W 300 最大功率点的工作电压 Max Power Voltage Vmp V 32 6 最大功率点的工作电流 Max Power Current Imp A 9 21 开路电压 Open Circuit Voltage Voc V 39 6 开路电流 Short Circuit Current Isc A 9 64 Website www znshine com Address 1 Zhixi...

Reviews: