2.3 Specifications
2.3.1 Dimensions
419.10 mm (16.5
”
) x 336.55mm (13.25
”
)
2.3.2 Electrical
Electrical Specifications
Input
120/240 VAC
50/60 Hz, 2.5 AMPS
240 VAC
50/60 Hz, 1.25 AMPS
Output
28 VDC @ 7.6 AMPS max.
Chlorine
1.64 lb. (744 gm) / 24 Hr.
External
Control
ORP/External Control Connector
AquaLink RS485 Connector
Table 4. Electrical Specifications
2.4 Circulation
This section will describe three basic plumbing
configurations along with equipment required for
each. Please ensure that the cell is the last piece
of equipment installed in the circulation system.
2.4.1 Single Body
(Pool Only Configurations)
A pool only configuration uses a single filter pump
and filter to circulate and filter a single body of
water.
2.4.2
Dual Body System, Shared Equipment
(Pool & Spa Combination)
A pool & spa combination configuration uses a
single filter pump and filter to alternate circulation
and filtration between two bodies of water.
2.4.3
Dual Body System, Separate Equipment
(Pool & Spa Dual Equipment)
A pool & spa dual equipment configuration uses a filter
pump and filter for each body of water, the pool and
the spa. Heaters may be shared or plumbed in
separately.
2.5 Quality Promise
As industry leaders committed to giving you
the perfect pool experience, we-
Promise to maintain the highest quality standards
in all areas of operation.
Promise to use high quality materials and world-
class processes to manufacture our products.
Promise that your equipment will arrive completely
tested in pool environments, inspected and quality-
assured for reliability and durability.
We stand by our promise.
Our promise is backed by dedicated support and
our written express product warranty.
For technical assistance please call 1-800-822-
7933
What you say matters. Tell us what you think by
calling
1-760-734-8844
or
feedback@zodiac.com for questions or input.
2.6 Required Tools and Equipment
Please ensure that the following tools and
equipment are available to the installer at the time
of install.
2.6.1
Tools
Safety Eyewear
Gloves
Screwdrivers
Combination pliers
Tape Measure
Voltage meter
PVC cutters
CPVC Cement
¼”
Hex Drive
Drill
2.6.1
Materials Supplied by the Installer
Section 3. Installing the Cell
WARNING
The Jandy
TruClearXL
chlorine generating
electrolytic cell must be installed outdoors only.
The cell must be installed horizontally to avoid
buildup of flammable gases which can result in
FIRE OR EXPLOSION.
The cell is intended for outdoor installation only. It
will need to be installed as the last piece of
equipment in the water system.
1. Determine the desired location for the cell as
Flexible Conduit
Conduit Connectors and Reducer Rings
Wire Connectors (wire nuts)
Wire High Voltage #12 AWG Minimum
Mounting Screws
Wall anchors or expansion anchors as needed
High Voltage Breakers
Wire Low Voltage - 4 conductor
Min. #22 AWG Communication Cable (Insulation Colors:
Red, Black, Yellow, Green)