Page 46
Nature
2®
Fusion Soft Installation and Operation Manual
7.3
Level 2 Service Codes
If you encounter a Level 2 Service Code, contact a quali
fi
ed service representative.
Code Number
Possible Cause
Corrective Action
180
Heated sensor element not heating.
(Generates 172 code)
Contact a quali
fi
ed service representative.
181
Flow sensor temperature sensor failure.
(Generates 172 code -
fl
ow sensor service)
Contact a quali
fi
ed service representative.
182
Salinity Sensor sees less than 0.2 gpl of salt, no salt
in pool or sensor air locked.
(Generates 175 code –
fl
ow sensor air lock)
Contact a quali
fi
ed service representative.
183-186
Flow salinity sensor temperature probe error codes.
(They will all generate 172 codes which indicate
fl
ow
sensor service is required)
Contact a quali
fi
ed service representative.
187
Power supply either too low or too high. (Generates
173 - Low input voltage code if Level 2 code 188 is
present) (Generates 170 code if 188 is not present)
Contact a quali
fi
ed service representative.
188
VAC input voltage is too low.
(Generates 173 code if Level II code 187 is present)
Contact a quali
fi
ed service representative.
189
Relay not conducting in the forward direction.
(Generates 171 code - Backboard service)
Contact a quali
fi
ed service representative.
190
Relay not conducting in the reverse direction.
(Generates 171 code - Backboard service)
Contact a quali
fi
ed service representative.
191
High cell current (at upper limit of A/D converter) and
cell voltage below 19V.
(Generates 170 code front board service)
Contact a quali
fi
ed service representative.
192
High cell current and cell voltage below 19V.
(Generates 171 code – Backboard service)
Contact a quali
fi
ed service representative.
193
Measured signi
fi
cant cell current when SCRs were
turned off.
(Generates 170 code – front board service)
Contact a quali
fi
ed service representative.
194
Cell Current is 85% lower than desired and cell
voltage above 19V.
(Generates 125 code - Cell dirty or needs replacement)
Contact a quali
fi
ed service representative.
195
Salinity invalid due to out of range measurements
caused by power board error.
(Generates 170 code – front board service)
Contact a quali
fi
ed service representative.
7.4
Additional Letter Codes
Code
Condition
Reason
EC
External Control
ORP unit or external controller has shut off chlorine production.
Lo
Low Temperature Cutoff
Temperature of Pool is < 50ºF (10°C). Chlorine production stopped.
bo
Boost
In “Boost” mode unit will operate at 100% production for 24 run time hours.
HH
High-High
Input has exceeded Maximum Range.
JA
AquaLink
®
RS Online
AquaLink RS is controlling the Nature
2
Fusion Soft and desired output
percentages.
Jb
Boost (AquaLink RS Interface)
AquaLink RS is controlling the Nature
2
Fusion Soft and “Boost” is active.